ENTEGRIS, INC.
Customer Service Tel. 763-502-0200 Customer Service Fax 763-502-0300
5
NT® PRESSURE T RAN SD UCER USE R GUIDE
NT® PRESS URE TRANSDUCER USER GUIDE
4
Customer Service Tel. 763-502-0200 Customer Service Fax 763-502-0300
ENTEGRIS, INC.
Identifying Nonstandard
Product Configurations
CODE
BASE MODEL
4250
Flow-Through Vacuum Pressure Transducer
CODE
PRESSURE RANGE
030V
-12 to 30 PSIG (-83 to 207 kPa)
060V
-12 to 60 PSIG (-83 to 414 kPa)
100V
-12 to 100 PSIG (-83 to 650 kPa)
CODE
INLET/OUTLET PORT CONNECTION TYPE
F02
1/4
″
Flaretek®
F03
3/8
″
Flaretek®
F04
1/2
″
Flaretek®
F06
3/4
″
Flaretek®
F08
1
″
Flaretek® (030G, 060G types only)
CODE
ELECTRICAL CONNECTOR TYPE
B06
FEP-jacketed 6
′
pigtail electrical cable
B12
FEP-jacketed 12
′
pigtail electrical cable
B30
FEP-jacketed 30
′
pigtail electrical cable
D00
3-pin polypropylene connector
D06
3-pin polypropylene connector and 6
′
PVC-jacketed mating cable
D12
3-pin polypropylene connector and 12
′
PVC-jacketed mating cable
D30
3-pin polypropylene connector and 30
′
PVC-jacketed mating cable
CODE
ELECTRICAL OUTPUTS
A
4-20 mA (12-28 VDC input)
CODE
PRIMARY/SECONDARY SEAL
U1
Kalrez® 4079/Viton® (default)
U2
Kalrez® 1050/Viton®
U3
Kalrez® 6375 UP/Viton®
S1
Kalrez® 4079/Kalrez® 4079
S2
Kalrez® 1050/Kalrez® 1050
S3
Kalrez® 6375 UP/Kalrez® 6375 UP
This User Guide applies to product
manufactured as standard NT
®
Pressure Transducers single-port
and flow-through models 4150 and
4250. Entegris also manufactures
nonstandard product to meet the
needs of specific applications.
Nonstandard product may have
different materials of construction,
accuracy specifications, performance
and other specifications that differ-
entiate the nonstandard product
from the standard offering.
NOTE:
Nonstandard pressure
transducers may be identified by
the model number found on the
product label.
Nonstandard
single-port pressure
transducers
, model 4150 product
line, are identified with a “
P
” fol-
lowed by a number code.
For example, part number
4150-030V-F02-B06-A-
P04
the “P04” designates the product as a
nonstandard product manufactured
to certain specifications designated
under the “P04”code.
Nonstandard
flow-through pressure
transducers
, model 4250 product
line, are identified with a “
T
” fol-
lowed by a number code.
For example, part number
4250-030V-F02-B06-A-
T02
the “T02” designates the product as a
nonstandard product manufactured
to certain specifications designated
under the “T02” code.