P/N 01-1040855 | Rev. E 02/18 | Entegris, Inc.
4
PRIMELOCK FITTING HANDHELD INSERTION TOOL
5. Slide the tube onto the mandrel until it stops.
6. Clamp the tube in place.
7. If the tubing is not held firmly, clean the tubing and
clamp with an IPA wipe.
8. Rotate the handle clockwise, driving the insert
into the tube until the tube contacts the mandrel
shoulder.
CAUTION: Failure to follow 1⁄4" insert instructions
may result in the insert remaining on the mandrel
after installation.
9. For 1⁄4" insert installation, there are two methods to
properly eject the mandrel from the tube assembly.
See steps 9a or 9b and 9c.
9a. Hold the ejection collar while rotating the
handle in a counterclockwise direction until
the mandrel is free from the tube assembly.
OR
9b. Unclamp the tube, and then rotate the handle
in a counterclockwise direction.
9c. Push the ejection collar forward until the tube
assembly is ejected from the mandrel.
Mandrel shoulder
Ejection
collar
Ejection
collar