Entegris, Inc. | P/N 01-1040855 | Rev. E 02/18
5
PRIMELOCK FITTING HANDHELD INSERTION TOOL
10. For 1⁄4" insert installation, the insert must be
pressed entirely into the tube, at a minimum
flush with the end of the tube or until the tube
contacts the mandrel shoulder.
Correct installation of insert.
Correct installation of insert.
Incorrect installation of insert.
COMPLETING THE FITTING CONNECTION FOR ALL SIZES
—
1. Slide the tubing assembly onto the fitting.
2. Start by hand-tightening the nut.
3. Place the PrimeLock wrench over the ribs of
the fitting nut and rotate clockwise. Tighten the
nut until the connection verification ring creates
audible clicks and the leading edge of the nut
travels under the connection verification ring.
NOTE: Do not overtighten to the point where the
nut bottoms out on the fitting body.
1"– 1
1
⁄
4
" sizes
1
1
⁄
2
" size