132
dataPAC User’s Guide
Chapter 4 - Off Route Analysis with the dataPAC
Tach/Gear Box
The Tach/Gear Box parameters are used to configure the dataPAC to measure information
on a shaft that is inaccessible or “buried” in a gear box.
Note: This option is not available if Trigger Control is set to None.
z
Trigger Pulses/Revolution - Indicates how many trigger pulses occur for each
revolution of the reference shaft. If this parameter is set to a value other than 1, there is
an initial phase angle ambiguity.
z
Tooth Count - Indicates how many teeth are present on the external shaft and the
internal shaft. If these values are set to 1, then the external shaft trigger is used directly.
Otherwise, the external reference is converted to a new reference that matches the
speed of the internal shaft. In this case, the phase measurement is only relative.