194
dataPAC User’s Guide
Chapter 5 - Balancing Measurements
4.
With the Edit Trial Weight Angle - Plane 1 window open, enter the angle at which you
are about to attach to the rotor in the first plane. When your entry is complete, press
<DONE>. To cancel, press <SHIFT><F5> (Abort).
If the machine has no vanes or blades, the trial weight location should be specified in
degrees (0 - 359). If you entered the number of vanes or blades earlier in the procedure,
the location is specified in positions (vanes or blades), from 1 to the total number of
vanes or blades.
Notice that after you enter the trial weight, the lower half of the dataPAC display
indicates the initial vibration in both planes, as well as the trial weight just entered. The
dataPAC updates the summary display as you compete each step of the balancing
operation.
5.
Attach the plane 1 trial weight to the rotor. The trial weight must be placed at the angle
previously established.
6.
With the trial weight attached securely, restart the machine and allow it to reach normal
operating speed.
7. Press <STORE> to begin taking a trial weight measurement.