Two Plane Balancing with a Reference Trigger
dataPAC User’s Guide
197
Adding the Correction Weights and Taking a Residual Measurement
1.
Attach correction weights. The dataPAC calculates and displays a recommended
balancing weight labeled “Correction” on the dataPAC display. There are two
correction weights, one for each plane. The “Position” column indicates where to attach
the correction weight.
z
For rotors with zero positions, the position is shown in degrees, in the direction of
rotation set in Weight Placement, from the 0° mark.
z
For rotors with multiple “positions” or vanes, the Position column indicates on
which positions the weights must be added. The 0° position is considered position
1, and the other positions are numbered sequentially, in the direction of rotation.