Installing the Device
3-4
Installation
Figure 3-1
Tabletop or Shelf Installation
3.3.2
Rackmount Installation
To install the 2H258-17R in a 19-inch rack, Enterasys Networks includes a strain-relief bracket for
cable management and an accessory kit containing the rackmount brackets, and mounting screws
to attach the rackmount brackets and strain-relief bracket.
Guidelines for the Rackmount Installation
The installation site must be within reach of the network cabling and meet the requirements listed
below:
•
An appropriate grounded power receptacle must be located within seven feet of the location.
•
Maintain a temperature of between 5
°
C (41
°
F) and 40
°
C (104
°
F) at the installation site with
fluctuations of less than 10
°
C (18
°
F) per hour.
CAUTION:
To ensure proper ventilation and prevent overheating, leave a minimum
clearance space of 5.1 cm (2.0 in) at the left, right, and rear of the 2H258-17R.
WARNING:
Before installing the 2H258-17R
into a rack, ensure that the rack supports
the device(s) without compromising the stability of the rack. Otherwise, personal injury
and/or equipment damage may result.
3068-02
A = 15 cm (6 in)
B = 57 cm (22.5 in)
C = 53 cm (21 in)
C
B
A
D
D = 213 cm (7 ft)