Release Notes
Known Issues with this Release
RiverMaster™ Version 3.5
Page 13 of 18
AVN-RMRN-R312
IKE Site-to-Site Tunnels to an ANG/APS Must Be Initiated by
a Remote ANG
Internet Key Exchange (IKE) tunnels built between a Local Aurorean
Network Gateway and a Remote ANG (site-to-site configuration) must be
initiated by the Remote ANG when the Local ANG consists of an ANG/APS
pair. An IKE site-to-site tunnel originating from a Remote ANG connecting
another standalone (Local) ANG is permitted, however.
IPSec/IKE Authentication Unavailable on Paired APS/ANGs
Due to a potential security risk in communications between an APS and
ANG, an APS/ANG pair can not initiate an IKE security association with
another APS/ANG pair. Only IRPP authentication is available in this
configuration as set on RiverMaster, not IPSec/IKE.
RIPv2 Works Improperly if Export Routes Disabled
If you have configured RIP v.2 to import routes only, the protocol will not
work correctly on the ANG due to the failure of GATED to join the RIPv2
multicast group (224.0.0.9). This problem can be remedied by taking one of
the following actions:
!
Create a static route on the ANG Trusted interface
!
Use RIPv1 only
Refer to the RiverMaster Administrator’s Guide for more information.
TeeChart Error after Installation Requires Printer Reinstall
While opening RiverMaster for the first time following installation, if your
RiverMaster computer displays an Error 317 message referencing the
TeeChart.ocx
file, perform the following steps:
1
Check to see if there is a printer defined on the RiverMaster computer
by double-clicking the My Computer icon on your desktop.
2
Click the Printers icon.