Troubleshooting Checklist
DFE-Platinum Series Hardware Installation Guide 4-5
User parameters (IP
address, device and
module name, etc.)
were lost when the
module power was
cycled, the front
panel OFFLINE/
RESET switch was
pressed.
Position of Mode switch
(7), Persistent Data Reset,
was changed sometime
before either cycling
power or pressing the
OFFLINE/RESET switch,
causing the user-entered
parameters to reset to
factory default settings.
Clear Persistent Data that
was set through Local
Management.
The module was moved
either from slot-to-slot or
from chassis-to-chassis.
Reenter the lost parameters as necessary. Refer to the
Enterasys Matrix DFE-Platinum Series Configuration
Guide
for the instructions to configure the device.
If the problem continues, contact Enterasys Networks
for technical support.
Table 4-2 Troubleshooting Checklist (continued)
Problem
Possible Cause
Recommended Action