background image

THE CUMULATIVE LIABILITY OF ENTERASYS TO YOU FOR ALL CLAIMS RELATING TO THE PROGRAM, 
IN CONTRACT, TORT OR OTHERWISE, SHALL NOT EXCEED THE TOTAL AMOUNT OF FEES PAID TO 
ENTERASYS BY YOU FOR THE RIGHTS GRANTED HEREIN. 

8.

AUDIT RIGHTS.

You hereby acknowledge that the intellectual property rights associated with the Program are of 

critical value to Enterasys and, accordingly, You hereby agree to maintain complete books, records and accounts showing 
(i) license fees due and paid, and (ii) the use, copying and deployment of the Program. You also grant to Enterasys and 
its authorized representatives, upon reasonable notice, the right to audit and examine during Your normal business hours, 
Your books, records, accounts and hardware devices upon which the Program may be deployed to verify compliance with 
this Agreement, including the verification of the license fees due and paid Enterasys and the use, copying and deployment 
of the Program. Enterasys’ right of examination shall be exercised reasonably, in good faith and in a manner calculated 
to not unreasonably interfere with Your business. In the event such audit discovers non-compliance with this Agreement, 
including copies of the Program made, used or deployed in breach of this Agreement, You shall promptly pay to Enterasys 
the appropriate license fees. Enterasys reserves the right, to be exercised in its sole discretion and without prior notice, to 
terminate this license, effective immediately, for failure to comply with this Agreement. Upon any such termination, You 
shall immediately cease all use of the Program and shall return to Enterasys the Program and all copies of the Program.

9.

OWNERSHIP.

This is a license agreement and not an agreement for sale. You acknowledge and agree that the 

Program constitutes trade secrets and/or copyrighted material of Enterasys and/or its suppliers. You agree to implement 
reasonable security measures to protect such trade secrets and copyrighted material. All right, title and interest in and to 
the Program shall remain with Enterasys and/or its suppliers. All rights not specifically granted to You shall be reserved 
to Enterasys.

10. ENFORCEMENT.

You acknowledge and agree that any breach of Sections 2, 4, or 9 of this Agreement by You 

may cause Enterasys irreparable damage for which recovery of money damages would be inadequate, and that Enterasys 
may be entitled to seek timely injunctive relief to protect Enterasys’ rights under this Agreement in addition to any and 
all remedies available at law. 

11. ASSIGNMENT.

You may not assign, transfer or sublicense this Agreement or any of Your rights or obligations 

under this Agreement, except that You may assign this Agreement to any person or entity which acquires substantially all 
of Your stock or assets. Enterasys may assign this Agreement in its sole discretion. This Agreement shall be binding upon 
and inure to the benefit of the parties, their legal representatives, permitted transferees, successors and assigns as 
permitted by this Agreement. Any attempted assignment, transfer or sublicense in violation of the terms of this Agreement 
shall be void and a breach of this Agreement.

12. WAIVER.

A waiver by Enterasys of a breach of any of the terms and conditions of this Agreement must be in 

writing and will not be construed as a waiver of any subsequent breach of such term or condition. Enterasys’ failure to 
enforce a term upon Your breach of such term shall not be construed as a waiver of Your breach or prevent enforcement 
on any other occasion.

13. SEVERABILITY.

In the event any provision of this Agreement is found to be invalid, illegal or unenforceable, the 

validity, legality and enforceability of any of the remaining provisions shall not in any way be affected or impaired 
thereby, and that provision shall be reformed, construed and enforced to the maximum extent permissible. Any such 
invalidity, illegality or unenforceability in any jurisdiction shall not invalidate or render illegal or unenforceable such 
provision in any other jurisdiction.

14. TERMINATION.

Enterasys may terminate this Agreement immediately upon Your breach of any of the terms and 

conditions of this Agreement. Upon any such termination, You shall immediately cease all use of the Program and shall 
return to Enterasys the Program and all copies of the Program.

Summary of Contents for Matrix N7 7C107

Page 1: ...hassis Installation Guide 1 4 5 6 7 2 3 50 60Hz LINE 2 100 125V 12A 200 240V 6A 50 60Hz LINE 1 100 125V 10A 200 240V 5A POWER FAN PS1 50 60Hz LINE 2 100 125V 12A 200 240V 6A 50 60Hz LINE 1 100 125V 10...

Page 2: ......

Page 3: ...Enterasys Networks Inc 50 Minuteman Road Andover MA 01810 2004 Enterasys Networks Inc All rights reserved Part Number 9033851 04 August 2004 ENTERASYS NETWORKS ENTERASYS MATRIX LANVIEW MATRIX NETSIGHT...

Page 4: ...tal apparatus does not exceed the class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le pr sent...

Page 5: ...ntspricht den folgenden Richtlinien 47 CFR Parts 2 and 15 CSA C108 8 89 336 EEC EN 55022 EN 61000 3 2 EN 61000 3 3 EN 55024 AS NZS CISPR 22 VCCI V 3 VCCI NOTICE This is a class A product based on the...

Page 6: ...Networks Ltd Nexus House Newbury Business Park London Road Newbury Berkshire RG14 2PZ England Conformance to Directive s Product Standards EC Directive 89 336 EEC EN 55022 EN 55024 EC Directive 73 23...

Page 7: ...ISIONS THE LICENSE THE DISCLAIMER OF WARRANTY AND THE LIMITATION OF LIABILITY IF YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT OR ARE NOT AUTHORIZED TO ENTER INTO THIS AGREEMENT ENTERASYS IS UNWILLI...

Page 8: ...product of the Program or the technology if such foreign produced direct product is subject to national security controls as identified on the U S Commerce Control List or iii if the direct product o...

Page 9: ...rs All rights not specifically granted to You shall be reserved to Enterasys 10 ENFORCEMENT You acknowledge and agree that any breach of Sections 2 4 or 9 of this Agreement by You may cause Enterasys...

Page 10: ......

Page 11: ...LANVIEW LEDs 2 2 2 3 1 Power Supply LEDs 2 2 2 3 2 Fan Tray LED 2 4 3 MATRIX N7 CHASSIS SETUP 3 1 Unpacking the Matrix N7 Chassis 3 1 3 2 Setting Up the Matrix N7 Chassis 3 4 3 2 1 Order of Installati...

Page 12: ...x Contents A SPECIFICATIONS AND REGULATORY COMPLIANCE A 1 Physical Specifications 1 1 A 2 Power Supply Requirements 1 2 A 3 Environmental Requirements 1 2 A 4 Regulatory Compliance 1 2...

Page 13: ...Rubber Feet Placement 3 5 3 3 Installing the Cable Management Bar 3 6 3 4 Shelf Installation 3 8 3 5 Rack Mounting the Matrix N7 Chassis 3 9 3 6 ESD Grounding Receptacle 3 10 3 7 Installing the Power...

Page 14: ...xii Tables Table Page Tables 2 1 Power Supply PS LED Status Definitions 2 3 2 2 Fan Tray LED States and Their Definitions 2 4...

Page 15: ...nd defines conventions used throughout this document Chapter 1 Introduction describes the features and capabilities of the Matrix N7 chassis and how to get help Chapter 2 Installation Requirements and...

Page 16: ...e accessed on the World Wide Web using the following URL http www enterasys com support manuals DOCUMENT CONVENTIONS The following conventions are used in this guide NOTE The Matrix N7 chassis support...

Page 17: ...eath due to an electrical hazard RIESGO ELECTRICO Advierte contra una acci n que pudiera resultar en lesi n corporal o la muerte debido a un riesgo el ctrico ELEKTRISCHER GEFAHRENHINWEIS Warnung vor s...

Page 18: ...Document Conventions xvi About This Guide...

Page 19: ...single IP address The Matrix N7 chassis uses a distributed switching architecture allows hot swapping of the DFE modules supports redundant power supplies and can be installed as a freestanding unit o...

Page 20: ...Chassis 7C107 Fan tray 6C407 Module slots 7 total Redundant power supplies 6C207 3 2 PS1 PS2 1 4 5 6 7 2 3 50 60Hz LINE 2 100 125V 12A 200 240V 6A 50 60Hz LINE 1 100 125V 10A 200 240V 5A POWER FAN PS1...

Page 21: ...load sharing 50 5 of the Matrix N7 chassis power load If one power supply fails the other power supply supports the entire load of the chassis without interruption to network traffic Refer to Section...

Page 22: ...o 220 Vac and a frequency between 50 and 60 Hz See the operating specifications in Appendix A No additional adjustments are necessary For installations in North America two 15 A power cords are requir...

Page 23: ...ion of any action s already taken to resolve the problem e g changing mode switches rebooting the unit etc The serial and revision numbers of all involved Enterasys Networks products in the network A...

Page 24: ...Getting Help 1 6 Introduction...

Page 25: ...helf must be able to support 80 kilograms 176 pounds of static weight To install the Matrix N7 chassis as a rack mounted unit care must be taken to ensure that the rack used will support the unit and...

Page 26: ...ed PS1 and PS2 The DFE modules for the Matrix N7 chassis are equipped with a firmware based management tool which provides the capability to configure one or more DFE modules and access chassis power...

Page 27: ...s Condition PS1 PS2 Load PS1 LEDs PS2 LEDs POWER FAN POWER FAN 1 ON OFF Amber Green Red Red 2 OFF ON Red Red Amber Green 3 ON Out of chassis Green Green Off Off 4 Out of chassis ON Off Off Green Green...

Page 28: ...different states of the fan tray LED Figure 2 2 Fan Tray LED Fan tray LED Table 2 2 Fan Tray LED States and Their Definitions LED Color Status Green All fans are operating normally Red One or more fan...

Page 29: ...o unpack the Matrix N7 chassis refer to Figure 3 1 which includes numbers that correspond to the steps below and proceed as follows 1 Cut the two shipping straps fastening the corrugated box to the sk...

Page 30: ...d hardware 7 Lift and remove the styrofoam cap from the top of the chassis Save for reshipping if necessary 8 Remove and save the eight screws fastening left and right shipping brackets to the chassis...

Page 31: ...Unpacking the Matrix N7 Chassis Matrix N7 Chassis Setup 3 3 Figure 3 1 Unpacking the Matrix N7 Chassis...

Page 32: ...48 26 centimeter 19 inch rack or other secure location Section 3 2 3 3 Attach the Electrostatic Discharge wrist strap Section 3 2 3 3 4 Install the power supply module s Section 3 2 4 3 2 2 Installing...

Page 33: ...ssemblies from their plastic bag in the shipping box 3 Locate the four tapped holes in the four corners on the bottom of the chassis Figure 3 2 Chassis Bottom Rubber Feet Placement 4 Screw in and hand...

Page 34: ...the cable management bar from the shipping box Ensure that there are four screws inside the bag with the cable management bar 2 Line up the two holes on each side of the cable management bar with the...

Page 35: ...inches of vertical spacing 2 Align the four holes in the ears of the shelf with those in the rack see Figure 3 4 A then fasten the shelf to the rack using four of the screws supplied with the rack 3...

Page 36: ...ck starting with the bottom holes and working toward the top of the chassis as shown in Figure 3 5 CAUTION Read Chapter 2 before completing the following procedure to ensure that all installation guid...

Page 37: ...Rack Mounting the Matrix N7 Chassis Rack mounting screws 5 per side 1 4 5 6 7 2 3 50 60Hz LINE 2 100 125V 12A 200 240V 6A 50 60Hz LINE 1 100 125V 10A 200 240V 5A POWER FAN PS1 50 60Hz LINE 2 100 125V...

Page 38: ...Supply You must install at least one 7C203 1power supply in the Matrix N7 chassis One power supply provides sufficient power for a fully loaded chassis but a second power supply can be installed to pr...

Page 39: ...el and using the other hand to support the power supply b Holding the power supply right side up align the power supply with the plastic guides on the bottom of the opening c With the power supply pro...

Page 40: ...d in Section 3 2 3 3 before handling the power supply module 2 Set the power supply 0 Power switch to 0 Mandatory power supply installed in slot PS1 Slotted screw Power supply handle Blank plate cover...

Page 41: ...rface or in an antistatic bag for future use Figure 3 8 Removing a Power Supply from a Powered Up Chassis CAUTION If you plan to operate the chassis with only one power supply make sure to install a c...

Page 42: ...AC Power Cords to the 6C207 3 NOTE If two power supplies are installed repeat the following procedure for each supply For redundancy using two 6C207 3 power supplies each of the four power cords from...

Page 43: ...hat allows for easy periodic cleaning and or replacement if a problem occurs with fan operation A flat blade screwdriver is needed to remove and reinstall the fan tray To remove and reinstall the fan...

Page 44: ...ssis 2 Hold the sides of the fan tray 3 Line up the rails on each side of the fan tray with the slot guides on the chassis 4 Slide the fan tray into the chassis until the faceplate of the tray is flus...

Page 45: ...Once the tray is in place tighten the two slotted screws to secure the tray to the Matrix N7 chassis Slotted screw 2 50 60Hz LINE 2 100 125V 12A 200 240V 6A 50 60Hz LINE 1 100 125V 10A 200 240V 5A PO...

Page 46: ...Removing and Reinstalling the Fan Tray 3 18 Matrix N7 Chassis Setup...

Page 47: ...07 chassis the 6C207 3 power supply module and the 6C407 fan tray module are as follows 7C107 Chassis 6C207 3 Power Supply Modules 6C407 Fan Tray Dimensions 77 47 H x 44 04 W x 36 83 D cm 30 5 H x 17...

Page 48: ...ility EMC requirements Input Frequency 50 to 60 Hz Input Voltage Current 2 x 100 to 125 Vac 10 5 A 2 x 200 to 240 Vac 5 5 A Input Power 1600 W Operating Temperature 5 C to 40 C 41 F to 104 F Storage T...

Reviews: