Module Description
80-14001000-03
2–5
2.2 Shelf Power Loading
Up to 12 Access modules (or 6 Backup modules) can be fitted into
Cabletron Systems SBU14C Shelf, or 4 Access (or 2 Backup) modules in
a SBU6C Shelf.
The modules require the following current (in mA) on the power rails:
Type
+5V
+12V
-12V
SBUQLS X21
275
0
0
SBUQLS V35
250
25
25
SBUQLS V24
250
25
25
SBUQHS X21
2,250
0
0
SBUQHS V35
2,200
25
25
SBUQHS V24
2,200
25
25
SBUQLB X21
1,050
600
0
SBUQLB V35
930
880
50
SBUQLB V24
250
620
50
SBUQHB X21
2,830
600
0
SBUQHB V35
2,780
880
50
SBUQHB V24
2,250
620
50
When installing modules into the Shelf, the installation engineer must
ensure that the shelf power supplies’ combined output can meet both the
overall power requirements and the individual rail current requirements
of all the cards in the shelf. (Please refer to the relevant manuals for this
information on other cards). This is true whether allowing for redundancy
or not.
Details of the power supplies’ capacity are in the SBU Systems manual.
Warning:
The Shelf and cards should be professionally installed by a
competent engineer. There are no operator serviceable parts
Summary of Contents for SBUQHS/QHB
Page 92: ...Menu Diagrams 80 14001000 03 12 3...
Page 93: ...Quad User Modules User Manual 80 14001000 03 12 4 12 1 2 SBUQLS QLB Operation Menu...
Page 94: ...Menu Diagrams 80 14001000 03 12 5 12 2 SBUQHS 12 2 1 SBUQHS QHB Operation Menu...
Page 95: ...Quad User Modules User Manual 80 14001000 03 12 6 12 2 2 SBUQHS QHB Configuration Menu...