Gigabit Ethernet Specifications
A-4 Specifications
Gigabit Ethernet Specifications
The
following
specifications
for
the
Mini
‐
GBICs
shown
in
Table A
‐
3
through
Table A
‐
10
meet
or
exceed
the
IEEE
802.3z
‐
1998
standard.
MGBIC-LC01/MGBIC-MT01 Specifications (1000BASE-SX)
MGBIC-LC03 Specifications (1000BASE-SX)
Table A-3 MGBIC-LC01/MGBIC-MT01 Optical Specifications
Item
62.5 µm MMF
50 µm MMF
Transmit Power (minimum)
-9.5 dBm
-9.5 dBm
Receive Sensitivity
-17 dBm
-17 dBm
Link Power Budget
7.5 dBm
7.5 dBm
Table A-4 MGBIC-LC01/MGBIC-MT01 Operating Range
Item
Modal Bandwidth @
850 nm
Range
62.5 µm MMF
160 MHz/km
2-220 Meters
62.5 µm MMF
200 MHz/km
2-275 Meters
50 µm MMF
400 MHz/km
2-500 Meters
50 µm MMF
500 MHz/km
2-550 Meters
Table A-5 MGBIC-LC03 Optical Specifications
Item
62.5/125 µm MMF
50/125 µm MMF
Transmit Power (minimum)
-9.5 dBm
-9.5 dBm
Transmit Power (maximum)
-3 dBm
-3 dBm
Receive Sensitivity
-20 dBm
-20 dBm
Link Power Budget
1
(Multimode Only)
1. The maximum drive distance (up to 2 km) depends on the quality of the installed multimode
fiber-optic cable segment. Use the Link Power Budget to calculate the maximum cable length of the
attached segment. The Link Power Budget must not exceed those specified in this table. The
MGBIC-LC03 input power must not exceed -3 dBm. Otherwise, saturation could occur.
10.5 dB
10.5 dB
Summary of Contents for SecureStack B2 B2G124-48P
Page 2: ......
Page 12: ...x ...
Page 21: ...x ...
Page 25: ...xiv ...
Page 29: ...Conventions Used in This Guide xviii About This Guide ...
Page 41: ...1000BASE T Network 2 4 Network Requirements ...
Page 81: ...Using the Reset Switch 4 10 Troubleshooting ...