Installing C2RPS-CHAS2 into the Rack
SecureStack C2 Installation Guide 2-5
Rack Mounting the Chassis
Refer
to
Figure 2
‐
2
and
proceed
as
follows
to
install
the
chassis
into
a
19
‐
inch
(48.3
‐
cm)
rack:
1.
Position
the
chassis
between
the
vertical
frame
members
and
align
the
mounting
holes
in
the
chassis
brackets
with
those
in
the
rack
frame.
2.
Fasten
the
chassis
securely
to
the
frame
using
four
mounting
screws
(user
‐
supplied).
Figure 2-2 Fastening the C2RPS-CHAS2 to the Rack
Caution:
To ensure proper ventilation and prevent overheating, leave a minimum
clearance space of 10.16 cm (4.0 in.) at the front and rear of the N-POE Chassis.
Precaución:
Para asegurar una buena ventilación y evitar que el sistema se
sobrecaliente, deje un espacio mínimo de 10.16 cm (4 pulgadas.) con respecto a la parte
delantera y trasera del chasis N- POE.
Warning:
Before installing the chassis into a rack, ensure that the rack can support the
device(s) without compromising the stability of the rack. Otherwise, personal injury and/or
equipment damage may result.
Advertencia:
Antes de instalar el chassis en un rack, asegurarse que el rack puede
soportar el(los) dispositivo(s) sin comprometer la estabilidad del mismo. De otra forma
puede suceder algun tipo de daño personal o del equipo.
Warnhinweis:
Schützen Sie sich vor Verletzungen und Geräteschaden, überzeugen Sie
sich vor der Installation des Chassis in das Rack, von dessen Stabilität.
1
C2RPS-CHAS2 chassis with one PSM
3
Mounting screws (supplied by user)
2
Rails of 19-inch rack
C2RPS-CHAS2
C2RPS-PSM
Power
À
Á
Á
Â
Â
Summary of Contents for SecureStack C2 C2RPS-CHAS2
Page 2: ......
Page 10: ...viii...
Page 16: ...Conventions Used in This Guide xiv About This Guide...
Page 22: ...Getting Help 1 6 Introduction...
Page 30: ...Connecting the PSM Cables and AC Power Cords 2 8 Installation...