WS-AP3705i Installation Procedures
2-2
Installation
–
includes mount plate; plastic mount rivet; 3 1.5” wall screws; 3 wall anchors for hollow
core or plasterboard; 2 machine screws
•
Protruded drop ceiling mount bracket
–
Enterasys WS-MB3705-02
–
includes 2 T-bar clips, mount plate with one T-bar clip attached, one loose; 2 screws for T-
bar clip; plastic mount rivet; no wall screws
WS-AP3705i Installation Procedures
This section describes the following installation procedures:
Mounting the WS-AP3705i to a Flat Drop Ceiling
A flat drop ceiling is a drop ceiling in which the ceiling tiles are flat across the T-bar rails on which
they rest. To mount the WS-AP3705i to a flat drop ceiling, you do not need an extra mounting
bracket. To attach the WS-AP3705i to a flat drop ceiling:
1.
Remove the ceiling panels around the drop ceiling rails where you intend to mount the AP.
Verify that the Ethernet cable that will connect to the AP can reach the AP at the point where
you plan to mount it.
Electrical Hazard:
This product should be installed and serviced by a qualified licensed technician,
electrician, or electrical maintenance person familiar with its operation and the hazards involved.
For information about...
Refer to page...
Mounting the WS-AP3705i to a Flat Drop Ceiling
2-2
Mounting the WS-AP3705i to a Protruded Drop Ceiling
2-3
Mounting the WS-AP3705i to a Wall
2-6
Mounting on a Junction Box
2-7
Mounting on an Existing Mount Plate
2-8
Note:
If mounting on a ceiling, you need to power the WS-AP3705i through an Ethernet cable with
POE, unless you have a power source above the ceiling with a cable that can reach to the point
where you are installing the WS-AP3705i.