ASTRONOMIC RELAY
(DTR-10)
ASTRONOMIC PHOTOCELL RELAY
(DTR-14)
MENUS :
Go to previous menu.
Go to next menu.
Scrolling between menus or decrease related value.
Pushing this button 3 seconds on DTR-10s main menu,
C1 relay position will be changed manually.
Selecting Lock Mode at DTR-14, C1 relay will be on/off on
main menu.
Scrolling between menus or increase related value.
Pushing this button 3 seconds on DTR-10s main menu,
C2 relay position will be changed manually.
Selecting Lock Mode at DTR-14, C2 relay will be on/off on
main menu.
ESC button
SET button
DOWN button
UP button
:
:
:
:
Safety Precautions
If below precautions are not properly observed and carried out, it can
cause to physical accident or damage to the device and installation.
Disconnect power before working on the device.
When device is connected to the network, do not remove the front panel.
Do not clean the device with solvent or similar items. Only clean with
dried cloth.
Verify correct terminal connections before operate the device.
Connect the device to the electrical panel.
Electrical equipment should be serviced only by your competent seller.
No responsibility is assured by the manufacturer or any of its
subsidiaries for any consequences rising out of the use of this
material.
DTR-10/14 which has a real time clock, is an electronic timer that calculate
the sunset and sunrise periods automatically. It designed for controlling
the devices which are connected to its contacts according to sunset,
sunrise and the time periods which are proggrammed by the user.
DTR-14 has also a photocell option in addition to above features.
1 ) PROGRAM (PROG) :
In this menu, program settings can be done.
Only one function ON or
OFF can be assigned to each program. Only one of TIME, SUNRISE
or SUNSET functions can be selected (assigned) for this function. The
day and/or days of active can be selected separately for this program.
4 different program assigned in order to make eaiser the using of device
by switch it ON at sunset time and switch OFF at sunrise time. These
programs which are assigned as default, can be deleted or changed by
the user.
1.3)
C1 / C2 relay selection ( / ):
C1 or C2 relay can
be selected via P01-C1 or P01-C2. 2 different loads can be controlled
with different functions in this way.
1.4) ON/OFF selection ( / ) / ( / ) :
In this
menu, it is selected that whether selected C1 or C2 relay will switch on or
switch off.
1.5)
Function selection ( / / / ) :
Function
selection is done in this menu. 1 function can be selected for each program.
4 functions exist: Photo, time, sunset and sunrise.
(PHOTO function
available only for DTR-14)
In order to use the photocell function, photocell sensor and auxiliary
supply always must be connected.
(Available only for DTR-14)
The loads connected to the C1/C2 relays do not function if auxiliary
supply is off. Even relay status can be mentioned as on ( ve
/veya ), but auxiliary supply is a must for the functionality.
If the auxiliary supply does not exist, device passes to sleep mode
and display disappears. However, real time clock and related functions
continue to operate. If 4 buttons are pressed at the same time, main menu
displays and so user can see or change all settings.
1
C1 relay can be switched off at all weekdays via photocell function by
using P02 program.
As above example, relay will switch on at 18:00 PM for all weekdays via
time function.
NOTE :
Device calculates the sunrise and sunset times automatically
according to the summer/winter time and coordinate information which are
set by user.
Device can switch on&off once per day via photocell function. Device can
not switch on/off more than once.
1.5.1)
( )
When photocell sensor perceives the light, ( ) symbol lights.
If lights do not exist, this symbol does not light.
C1 relay can be switched on at all weekdays via photocell function by
using P01 program.
As above example, if photocell sensor perceives the darkness, after 10
seconds, photocell symbol ( ) does not light on the main menu and the
relay switches on within 1 minute.
As above example, if photocell sensor detects the daylight, after 10
seconds, photocell detected symbol ( ) lights on the main menu and the
relay switches off within 1 minute.
NOTE:
Device can only switch on between 12:00 AM and 24:00 PM. Device
can not switch on except this time interval.
NOTE:
Device only can switch off between 24:00 PM and 12:00 AM. Device
can not switch off except this time interval.
1.5.2)
( ) Selected relay can be switched on/off at defined
time period.
SET
SET
SET
SET
ESC
SET
SET
SET
ESC
SET
SET
SET
SET
Main Display
SU
C2:
C1:
00
02
04
06
08
10
12
14
16
22
20
18
24
When programmed or in program menu, related
relays are programmed as ON. Relay contact position looks like
on the figure at left side. Relay contacts seem at monitor as
or .
When programmed or in program menu, related
relays are programmed as ON. Relay contact position looks like
on the figure at left side. Relay contacts seem at monitor as
or .
CR-2032 reserve battery should only be changed by authorized service.
For long time reserve, battery CR-2032 is used. The shelf life of this
battery is 5 years, if the device is continously voltage supplied. If the device
is not continously voltage supplied and waited in the shelf, the life of the
battery is 2-3 years (changes according to humidity of the shelf).
There are two reserves in the device. Programmed data is protected
by these reserve against power failure.
If power fails for 6-10 hours, programmed data is protected by super
capacitor and device continues to its operation. During this time battery
(CR2032) is not used; so battery life extends.
For short time, super capacitor is used:
SET
SET
SET
SET
SET
ESC
SET
SET
SET
ESC
SET
SET
SET
SET
Main Display
SU
C2:
C1:
00
02
04
06
08
10
12
14
16
22
20
18
24
MANUEL USING :
Using DTR-10s relay on manuel mode, display must be on main menu.
Pushing DOWN ( ) button during 3 seconds C1 relay; pushing UP ( )
button during 3 seconds C2 relay; After 3 seconds releasing this button
related relays position will change. If relays at ON position it will be OFF,
at OFF position it will be ON. Lock Mode selection does not affect this
application (For details please look at LOCK MODE section).
Using DTR-14s relay on manuel mode, Lock Mode must be selected. On
main menu Lock sign ( ) must be displayed. Changing C1 relay position
use Down ( ) button, for C2 relay use UP ( ) button.
Note: Push same button for returning previous position of relay.
C2:
C1:
00
02
04
06
08
10
12
14
16
22
20
18
24
MO
WE
FR
SA SU
TH
TU
ESC
SET
Day
Date
Time
Relay on/off situation
Lock Mode
ESC button
SET button
UP button
DOWN button
Photocell symbol
It represents the time
interval which relays will
switch ON.
(Available only for DTR-14)
SET
SET
SET
SET
ESC
SET
SET
SET
ESC
SET
SET
SET
SET
Main Display
SU
C2:
C1:
00
02
04
06
08
10
12
14
16
22
20
18
24
C1, C2
C1, C2
1.2) Enter / Delete settings ( / ) :
is used to
set a new program or to change the existing program. is used
to delete the existing program.
1.1)
Program selection
( ):
Device has 16 different programs.
User can assign 1 function to any program between P01-P16. Only 1 relay
can be selected via one program and also this relay can only be set as
switch on or switch off.
For instance; If the status of C1 relay is set as ON (switch on), 1 program
is used.
In order to switch off the relay which was set as ON before, another
program must be used (Such as 2nd program).
Star sign which exists after the program number ( ) represents that
the program is assigned.
There are 15 different program choices for DTR-10 ( ).
The relay, which is switched on via any program, can not be switched off
by deleting the related program. We can switch off the relay in two ways:
a)
Released with manually (for details please look at MANUAL USING
section).
b)
Enter the switch off time (OFF) for any relay. Delete the program after
the relay switched it off (OFF).
Related steps are mentioned as below: