background image

MENUS :

As above example, relay will switch on at 18:00 PM for all weekdays via

time function.

Sunset settings are similar with sunrise settings.

As above example, C1 relay will switch on 2 hours 30 minutes before the

sunrise time for all weekdays.

1.5.3) 

(              ) In this menu, sunset function is selected

As above example, C1 relay will switch off 1 hour 50 minutes before the

sunset time for all weekdays.

NOTE : 

Device calculates the sunrise and sunset times automatically

according to the summer/winter time and coordinate information which

are set by user.

Go to previous menu.

Go to next menu.

Scrolling  between  menus  or  decrease  related  value.

Relay position is change manually if press for 3 sec. in

start menu.

Scrolling  between  menus  or  increase  related  value.

ESC button

SET button

DOWN button

UP button

:

:

:

:

DTR-10t, which has a real time clock, is an electronic timer that calculate

the sunset and sunrise periods automatically. It designed for controlling

the devices which are connected to it’s contacts according to sunset,

sunrise  and  the  time  periods  which  are  proggrammed  by  the  user.

1 ) PROGRAM (       ) :

In this menu, program settings can be done. 

Only one function ON or

OFF can be assigned to each program. Only one of TIME, SUNRISE

or SUNSET functions can be selected (assigned) for this function. The

day and/or days of active can be selected separately for this program.

2 different program assigned in order to make eaiser the using of device

by switch it ON at “sunset” time and switch OFF at “sunrise” time. These

programs which are assigned as default, can be deleted or changed by

the user.

Related steps are mentioned as below:

If “0:00” is set, relay will be controlled at sunrise time. By this

feature, devices which are connected to the relays, can be

controlled after or before the sunrise time.

Relay can be controlled before or after the sunrise time according to the

entered  time  information.  This  value  can  be  set  as  hour  or  minute.

(Max: +9:59, Min: -9:59)

1.5.2) 

(                ) In this menu, sunrise function is enabled however

sunrise time is not set.

  

The output loads connected to the C1 relay do not function if

auxiliary supply is off. Even relay status can be mentioned as “on”

(         ), but auxiliary supply is a must for the functionality.

  If the auxiliary supply does not exist, device passes to sleep mode

and display disappears. However, real time clock and related functions

continue to operate. If 4 buttons are pressed at the same time, main menu

displays and so user can see or change all settings.

1.1)

 

Program selection

  

(               ) :

 Device has 15  different

programs. User can assign 1 function to any program between P01-P15.

Relay can be selected via one program and also relay can only be set as

“switch on” or “switch off”.

For instance; If the status of C1 relay is set as “ON (switch on)”, 1 program

is used.

In order to switch off the relay which was set as “ON” before, another

program must be used (Such as 2nd program).

Star sign which exists after the program number (              ) represents

that the program is assigned.

1.5.1) 

(        ) 

Selected relay can be switched on/off at defined

time period.

1

Safety Precautions

If below precautions are not properly observed and carried out, it can

cause to physical accident or damage to the device and installation.

Disconnect power before working on the device.

When device is connected to the network, do not remove the front panel.

Do not clean the device with solvent or similar items. Only clean with

dried cloth.

Verify correct terminal connections before operate the device.

Connect the device to the electrical panel.

  Electrical equipment should be serviced only by your competent seller.

No responsibility is assured by the manufacturer or any of its

subsidiaries for any consequences rising out of the use of this

material.

C2:

C1:

00
02
04
06
08
10
12
14
16

22

20

18

24

MO

WE

FR SA SU

TH

TU

ESC

SET

Day

1.2) Enter / Delete settings (            /            ) :

              is used to set

a new program or to change the existing program.

“           ” is used to delete the existing program.

1.3)

 Shows that C1 relay assigned to which program.

The relay, which is switched on via any program, can not be switched off

by deleting the related program. We can switch off the relay in two ways:

a) 

Switch off (OFF) the relay manually. (Check the LOCK section)

b)

 Enter the switch off time (OFF) for any relay. Delete the program after

the relay switched it off (OFF).

 

1.5) 

 

Function selection (           /              /             ) :

 

Function

selection is done in this menu. 1 function can be selected for each program.

3 functions exist: Time, sunset and sunrise.

 

1.4) ON/OFF selection (           /            ) : 

In this menu, it is selected

that whether selected C1 relay will switch on or switch off.

C1

C1

When  programmed                          in  program  menu,  C1  relay  is

programmed as ON. Relay contact position looks like on the figure

at left side. Relay contacts seem at monitor as         .

When  programmed                  in  program  menu,  C1  relay  is

programmed as ON. Relay contact position looks like on the

figure at left side. Relay contacts seem at monitor as      .

ASTRONOMIC RELAY 

(DTR-10t)

CR-2032 reserve battery should only be changed by authorized service.

For long time reserve, battery CR-2032 is used. The shelf life of this

battery is 5 years, if the device is continously voltage supplied. If the

device is not continously voltage supplied and waited in the shelf, the life

of the battery is 2-3 years (changes according to humidity of the shelf).

There are two reserves in the device. Programmed data is protected

by these reserve against power failure.

If power fails for 6-10 hours, programmed data is protected by super

capacitor and device continues to its operation. During this time battery

(CR2032) is not used; so battery life extends.

For short time, super capacitor is used:

MANUEL USE :

To use C1 relay, display must be in start menu. Whether LOCK mod (Ref.

LOCK menu) is selected or not, if pressed Down (   ) button for 3 sec.; at

the end of 3 sec.; if relay is on, it will be off and if relay is off, it will be on.

SET

SET

SET

SET

SET

ESC

SET

SET

SET

ESC

SET

SET

SET

SET

Main Display

SU

C2:

C1:

00
02
04
06
08
10
12
14
16

22

20

18

24

SET

SET

SET

ESC

SET

SET

SET

ESC

SET

SET

SET

SET

SET

Main Display

SU

C2:

C1:

00
02
04
06
08
10
12
14
16

22

20

18

24

SET

SET

SET

ESC

SET

SET

SET

ESC

SET

SET

SET

SET

SET

Main Display

SU

C2:

C1:

00
02
04
06
08
10
12
14
16

22

20

18

24

Date

Time

Relay on/off situation

Lock  Mode

ESC button

SET button

UP button

DOWN button

It represents the time

interval which relay will

switch ON.

Reviews: