background image

Geographical location, which device will be used in, can be set in this

menu.

For related settings, please refer to 

Table-1

.

If some missing or inaccurate data is entered, wrong sunrise and sunset

times are calculated.

Time zone (            ), latitude (             ) and longitude (            ) submenus

exist in this menu.

2 ) SWITCH ON & OFF NUMBER of RELAYS (           ) :

In this menu, switch on&off numbers are displayed for C1 relay. Device

counts once for switching on and once for switching off.

Count number of C1 can be reset

by selecting DELETE option.

DISPLAYS :

Settings, which are done in the 'menus' section, can be observed in this

section. It is not possible to set any parameter in this section.

On the main menu, dashes, which exist near the

numbers between '00-24', represent total working

time of C1 relay.

Displays can be observed by pressing ESC button.

4 ) REAL TIME SETTING (        ) :

Real time and date settings are done in this menu. Year, month, day, hour

and minute can be set respectively.

5 ) GEOGRAPHICAL LOCATION SETTING (        ) :

3 ) LOCK (MANUAL CONTROL) MODE (        ) :

Time difference (UTC/GMT) according to the Greenwich, London

is set. This value is '02' for Turkey. Negative time differences

must be subtracted from '24'. For example, time difference for

Mexico City is '-6' hours and so             value must be set as

'18'. (24-6=18)

A lock sign (  ) displays near the relay which is locked.

6 ) SUMMER / WINTER TIME SETTING (          ) :

In this menu, summer/winter time settings are done.

6.1) 

If Auto (         ) menu is selected, last sunday of March 02.00 AM

and last Sunday of October 03.00 AM are loaded. For Turkey and Europe,

automic mode is in use.

6.2)

 Date and hour also can be set by user manually via manual

(             ) menu.

First, month, day, hour and minute is set for summer tariff (   ) and then

same settings are done for winter tariff (    ).

2

SU

C2:

C1:

00
02
04
06
08
10
12
14
16

22

20

18

24

Latitude value is set in this menu. North (   )/South (   ) hemisphere

is selected and related degree value is set.

(For example, Istanbul, North (   ) 41°.

This display represents working time (cronogram) of

C1 relay and also working time internal which relay

will operate. As this example, C1 relay will switch on

for 4 hours between 18:00-22:00.

00
02
04
06
08
10
12
14
16

22

20

18

24

To prevent the operation of the program assigned the

lock menu is placed.

C2:

C1:

9 ) SERVICE MODE (            ):

Lets the user control and maintain in urgent situations. In order to choose

service mode, lock mode shouldn’t be selected before. In the main menu,

up and down buttons (      ) should be pressed 

at the same time.

 When

this mode is selected, assigned programs can not change the relay

position. “           ” and lock signs (  ) are displayed. In order to exit the

service mode, up and down buttons should be pressed at the same time.

Date information will be displayed instead of “           ”. Lock sign will be

removed. In case of escaping the “service mode”, the last program

continues its execution. For user safety, it is not possible to enter to lock

(        ) and factory settings (           ) modes, when service mode is

activated.

Regarding to assign programs, dashs which are next to the numbers of

00 - 24, represent for “switch on” and “switch off” time of the relay. Each

dash represents two hours.

Longitude value is set in this menu. If the longitude is east,

degree value is set directly. If the longitude is west, degree value

is subtracted from 360° and then entered. (For example, Istanbul,

East (e) 29°). For instance, longitude value is 99° west for Mexico

City and so longitude value must be set as '261'. (360-99=261)

Values which are mentioned in 

Table-1

 are calculated before. Therefore,

there is no need to calculate these values again.

Below diagrams show that how devices can be locked.

When LOCK mode is disabled, device continues to work by

the last program.

C2:

C1:

Below diagrams show that how LOCK menu can be disabled.

This display represents the sunrise time which is calculated

according to coordinate, season and real time settings. According

to this example, sunrise time is 05:30 AM
This display represents the sunset time which is calculated

according to coordinate, season and real time settings.

According to this example, sunset time is 18:38 PM.

If switch on time is set 19:01 instead of 18:00, “18-

20” interval does not have any dashes and also

working  time  becomes  02:59  instead  of  04:00.

24

00
02
04
06
08
10
12
14
16

22

20

18

ASTRONOMIC RELAY 

(DTR-10t)

C2:

C1:

00
02
04
06
08
10
12
14
16

22

20

18

24

SA

ESC

SET

C2:

C1:

00
02
04
06
08
10
12
14
16

22

20

18

24

SA

ESC

SET

C2:

C1:

00
02
04
06
08
10
12
14
16

22

20

18

24

SA

ESC

SET

C2:

C1:

00
02
04
06
08
10
12
14
16

22

20

18

24

SA

ESC

SET

It is shown “on” time of relay if the real time clock has passed 18:00.

1.6) Day selection (            /          , .......... ,            /          ) :

As last, working days for selected programs are set. This setting can be

done for all days starting from Monday.

If “YES” selected, program function is enabled for related day.

If “NO” selected, program function is disabled for related day.

As above example, program function is enabled for Monday, Wednesday

and Friday.

7 ) FACTORY SETTING (            ) :

In this menu, all settings are reset except hour and date. By selecting

          option, all programs are reset, counters are reset, relays, which are

switched on, are switched off, lock mode is disabled. Coordinates are

programmed according to Istanbul, season is set as auto and LCD contrast

value is set as '13'.

6.3) 

If summer/winter time application does not exist in the related

region,               option must be selected.

SET

SET

SET

SET

ESC

SET

SET

SET

SET

SET

SET

ESC

SET

SET

SET

Main Display

SU

C2:

C1:

00
02
04
06
08
10
12
14
16

22

20

18

24

SET

SET

SET

SET

SET

Main Display

SU

C2:

C1:

00
02
04

06
08
10
12
14
16

22

20

18

24

SET

ESC

Main Display

SU

C2:

C1:

00
02
04

06
08
10
12
14
16

22

20

18

24

C2:

C1:

C2:

C1:

C2:

C1:

SET

SET

Main Display

SU

C2:

C1:

00
02
04
06
08
10
12
14
16

22

20

18

24

SET

ESC

Main Display

SU

C2:

C1:

00
02
04
06
08
10
12
14
16

22

20

18

24

C2:

C1:

C2:

C1:

C2:

C1:

C2:

C1:

The programming of geographical zone for London is mentioned above.

SET

SET

SET

ESC

SET

SET

SET

SET

Main Display

SU

C2:

C1:

00
02
04
06
08
10
12
14
16

22

20

18

24

SET

SET

SET

ESC

Main Display

SU

C2:

C1:

00
02
04
06
08
10
12
14
16

22

20

18

24

Main Display

SU

C2:

C1:

00
02
04
06
08
10
12
14
16

22

20

18

24

SET

SET

SET

ESC

Main Display

SU

C2:

C1:

00
02
04
06
08
10
12
14
16

22

20

18

24

Main Display

SU

C2:

C1:

00
02
04
06
08
10
12
14
16

22

20

18

24

8 ) LCD CONTRAST SETTING (           ) :

LCD contrast value can be set between '0-15' by user.

SET

SET

SET

ESC

Main Display

SU

C2:

C1:

00
02
04
06
08
10
12
14
16

22

20

18

24

Main Display

SU

C2:

C1:

00
02
04
06
08
10
12
14
16

22

20

18

24

Reviews: