background image

CONTENTS 

COMPONENT LOCATIONS .................................................................................................... 1

 

WIRING DIAGRAM ................................................................................................. 1

 

INSTALLATION ........................................................................................................ 2

 

Opening the Keypad ............................................................................................ 2

 

Install the Electrical Box and Mounting Plate .................................................... 2

 

Final Keypad Installation ...................................................................................... 2

 

Keypad Wiring ............................................................................................... 3

 

Solid State Outputs ................................................................................................ 3

 

FACTORY DEFAULTS .......................................................................................................... 4

 

BASIC PROGRAMMING......................................................................................... 4

 

PROGRAMMING OPTIONS .................................................................................... 5

 

RESETTING KEYPAD .......................................................................................................... 6

 

Master Reset ................................................................................................... 6

 

Resetting the Master Code................................................................................... 6

 

AK-21W OPERATION .................................................................................................... 6

 

SPECIFICATIONS ......................................................................................................... 6

 

LINEAR LIMITED WARRANTY ................................................................................ 6

 

IMPORTANT !!! ............................................................................................... 6

 

FCC NOTICE ................................................................................................................... 6

 

INTRODUCTION

 

Linear’s AK-21W is a digital keyless entry system designed for access control 
applications. The keypad is housed in a rugged, die-cast metal enclosure and is 
designed to be mounted in a single-gang electrical box. The die-cast keys have 
bright, easy-to-read yellow graphics.

 

Up to 480 entry codes, from1 to 6 digits in length, can be programmed.They can 
activate either, or both, of the relay outputs.The “anti-passback” feature prevents 
using the same code again before the programmed time elapses.

 

All systemindicators and lights are long-lasting, solid-state LEDs. Two indicators 
showthe status of the entry system.The left indicator lights red to indicate power, 
then turns green when access is granted. The right indicator lights yellow when 
the keypad is in “lockout” condition (from too many incorrect code entries). The 
keypad’s courtesy light dimly illuminates the keys at all times. The courtesy light 
brightly illuminates the keys for two minutes after any key is pressed. An internal 
sounder beeps when each key is pressed. An internal jumper sets the sounder 
volume high or low.

 

The 

SENSE 

input can be used two ways. If programmed for “door sense” the 

input is wired to a normally closed switch on the door to detect when the door is 
open or closed. Forced entry or door ajar situations can then be detected. Using 
door sense, the “Auto-relock” feature will prevent “tailgating” by turning off the 
Main Relay output immediately when the door is closed after access has been 
granted. If the 

SENSE 

input is programmed for “inhibit”, the input can be wired 

to a “service” switch or automatic timer that will disable the Main Relay when 
required.

 

The 

REQUEST-TO-EXIT 

input can be wired to a pushbutton to provide 

codeless activation of Main Relay, Auxiliary Relay, Output #3, or Output #4 
(programmable).

 

The 

ALARM SHUNT 

output activates when access is granted. This output can 

be wired to shunt alarmcontacts on the access door/gate to prevent triggering of 
an alarm when authorized access occurs.

 

The AK-21W is powered from a 12-24 Volt AC or DC source. Power can be 
obtained from the access device or a separate power supply. The EEPROM 
memory retains all entry codes and programming, even without power. An 
internal jumper is providedtoreset themaster code.TheMainRelay has a5 Amp 
capacity. The Auxiliary Relay has a 1 Amp capacity. Two solid state outputs, 
capable of switching 100 mA to common, are programmable to signal forced 
entry, door ajar, lockout, alarmcircuit shunting, request-to-exit, and keypad active 
conditions.

 

FEATURES 

WEATHER RESISTANT DESIGN

For outdoor installation

 

KEYPAD   PROGRAMMABLE

No programmer required

 

480 ENTRY CODE CAPACITY

Ideal for small & medium traffic installations

 

1-6 DIGIT ENTRY CODE LENGTH

Flexible code length for different applications

 

4 INDEPENDENT OUTPUTS (TIMED/TOGGLED)

Each output’s action is programmable

 

4 INDEPENDENT TIMERS

Each output’s activation time is programmable

 

TWO FORM “C” (N.O. & N.C) RELAY CONTACTS

Main Relay 5-Amp @ 28 VDC capacity, 

Auxiliary Relay 1-Amp @ 28 VDC capacity

 

EACH ENTRY CODE CAN ACTIVATE EITHER OR BOTH RELAYS

Specific entry codes can grant access to different doors

 

TWO SOLID STATE OUTPUTS

Auxiliary outputs can indicate access status on external devices

 

TWO STATUS INDICATORS (2-COLOR RED/GREEN & YELLOW)

Displays access, lockout, and programming information

 

WHITE SOLID-STATE LED COURTESY LAMP

Programmable off/on/timed

 

PIEZO SOUNDER (TWO SELECTABLE VOLUME LEVELS)

Programmable for beeps during key presses and output activations

 

TIMED ANTI-PASSBACK

Disables entry code for a programmed time after use

 

AUTO-RELOCK

Releases the main relay as soon as the door shuts

 

KEYPAD LOCKOUT

Locks the keypad after too many incorrect entries

 

TACTILE KEY FEEL

Assures complete key presses

 

DOOR SENSE INPUT

For sensing door position to control auto-relock and door-ajar features

 

INHIBIT INPUT

For temporarily disabling access with a timer or switch

 

REQUEST-TO-EXIT INPUT

For codeless activation with a pushbutton

 

KEYPAD CAN BE POWERED FROM 12-24 VOLTS AC OR DC

Power can be supplied from a transformer, battery, or power supply

 

wwww.EntraPASS.com  

8641 S. Warhawk Rd., Conifer, CO 80433 - Tel: 303-670-1099 - Email: Patrick.McAllister@EntraPASS.com

 wwww.EntraPASS.com / 8641 S. Warhawk Rd., Conifer, CO 80433 - Tel: 303-670-1099 - Email: Patrick.McAllister@EntraPASS.com

Summary of Contents for E-PASS-21W

Page 1: ... Prog W grammin ng Instr ruction ns wwww EntraPASS com 8641 S Warhawk Rd Conifer CO 80433 Tel 303 670 1099 Email Patrick McAllister EntraPASS com wwww EntraPASS com 8641 S Warhawk Rd Conifer CO 80433 Tel 303 670 1099 Email Patrick McAllister EntraPASS com ...

Page 2: ...toshunt alarmcontactsontheaccessdoor gatetoprevent triggeringof analarmwhenauthorizedaccessoccurs The AK 21Wis powered from a 12 24 Volt AC or DC source Power can be obtained from the access device or a separate power supply The EEPROM memory retains all entry codes and programming even without power An internal jumperisprovidedtoresetthemastercode TheMainRelayhasa5Amp capacity The Auxiliary Relay...

Page 3: ...VDCMAX AUXILIARY REQUEST TO EXIT 6 EARTHGROUND 5 OUTPUT 3 COM 4 OUTPUT 3 3 AUXILIARY OUTPUTS REQUEST TO EXIT BUTTON TOALARM SYSTEM ALARM CONTACT 7 COM RELAY1 AMP 8 N C 28VDCMAX OUTPUT 4 2 OUTPUT 4 COM 1 100mAMAX TOCOMMON GROUND STAKE REQUIREDWIRING OPTIONALWIRING OTHERWIRING NOTES 1 ALARMSHUNT SET FORAUXILIARY RELAY 2 TERMINALBLOCK 2 TERMINAL8 SETFORDOORSENSE CAUTION IF THE UNIT IS AC POWERED MAKE...

Page 4: ...ITTHEBOTTOMTABOF THEFACEPLATEINTOTHE SLOTONTHEKEYPAD 4 SNAPTHETOP OFTHEKEYPAD INTOPLACE Install the Electrical Box and Mounting Plate The keypad is designed to fit into a single gang electrical box The box must be deep enough to accomodate the protective plastic enclosure Select a location near the controlled door and choose a convenient height for the keypad Be sure there is good wiring accessibi...

Page 5: ...ther a door sense or inhibit input Both features cannot be used at the same time To use the door sense feature to detect forced entry or door ELECTRIC DOOR STRIKE AK 21WREARVIEW TERMINAL BLOCK2 TB2 3 N O 4 COM 5 N C 6 7 8 TERMINAL BLOCK1 SENSE 8 COM 7 6 EARTHGROUND 5 4 3 TERMINAL MAIN RELAY 5AMPSMAX N C DOOR SENSE SWITCH GROUND STAKE ajar conditions install a normally closed door switch on the doo...

Page 6: ...will turn off until programming begins After a programming option number is entered the yellow indicator will blink This shows that the AK 21W is ready to accept the new programming data After the new data entry is complete the yellow indicator will flash while the data is being stored The green indicator will light if the data is accepted The red indicator will light if any programming data is en...

Page 7: ...ter too many incorrectentrycodeattempts Thelockouttimeis60seconds Press 1 3 Output Output OutputtoActivate 0 4 1 MainRelay 2 AuxiliaryRelay 3 Output 3 4 Output 4 0 NoOutput Main Relay On time Default 2 Seconds SetsthelengthoftimetheMainRelayactivateswhentriggered Press 2 1 Seconds Seconds Outputtimeinseconds 0 60 Auxiliary Relay On time Default 2 Seconds SetsthelengthoftimeAuxiliaryRelayactivatesw...

Page 8: ...s 3 00 W L Voltage 12 24Vo Current 30mAty Outputs MainRe Form Auxiliary Form Solidsta Short ENTAL perature 22 Fto Humidity 5 to95 LIMITED WAR oduct is warranted months The Warr ds only to wholesa distributionchanne ould inquire from th There are no obli damagesarisingo r otherindirect dam ofremoval installat iesformerchantabili ation Date as labeled rrantiesexpressor urnedfor warrantys ct Linear T...

Reviews: