COMPONENT LOCATIONS 

RED/GREEN 
POWER/ACCESS 
INDICATOR

 

YELLOW 
"LOCKOUT" 
INDICATOR

 

MASTER CODE 
RESET JUMPER 
(JP2)

 

BEZEL

 

TERMINAL 
BLOCK #2 
(TB2)

 

FACEPLATE

 

SOLID STATE 
WHITE LED 
DOWN LIGHT

 

TERMINAL 
BLOCK #1 
(TB1)

 

KEYPAD

 

MOUNTING 
PLATE

 

BEEPER 
LEVEL 
JUMPER (JP1)

 

Figure 1. Component Locations

 

WIRING DIAGRAM 

TYPICAL DOOR INSTALLATION WIRING

 

POWER 
SUPPLY

 

TERMINAL 

BLOCK 2

 

1 - AC OR DC

 

2 - AC OR DC

 

AK-21W TERMINALS

 

12-24 VOLT 

AC OR DC 

POWER

 

TERMINAL 

BLOCK 1

 

SENSE - 8

 

COM- 7

 

N.C. DOOR

SWITCH

ELECTRIC 

DOOR 

STRIKE

 

3 - N.O.

 

4 - COM

 

5 - N.C.

 

6 - N.O.

 

MAIN RELAY 

5 AMPS @

 

28 VDC MAX.

 

AUXILIARY

 

REQUEST-TO-EXIT - 6 

EARTH GROUND - 5 

OUTPUT #3 COM- 4

 

OUTPUT #3 - 3

 

AUXILIARY 

OUTPUTS

 

REQUEST 

TO EXIT 

BUTTON

 

TO ALARM

 

SYSTEM

 

ALARM 

CONTACT

 

7 - COM   

RELAY 1 AMP

 

8 - N.C.  

@28 VDC MAX.

 

OUTPUT #4 - 2

 

OUTPUT #4 COM- 1

 

100 mA MAX. 
TO COMMON

 

GROUND 

STAKE

 

REQUIRED WIRING 

OPTIONAL WIRING 

OTHER WIRING

 

NOTES:

 

1. ALARMSHUNT SET FOR AUXILIARY RELAY

 

2. TERMINAL BLOCK #2, TERMINAL 8 SET FOR DOOR SENSE

 

CAUTION

 

IF THE UNIT IS AC POWERED, 

MAKE SURE THE SECONDARY OF THE 
SYSTEM TRANSFORMER IS ISOLATED

 

FROM EARTH GROUND

 

Figure 2. Wiring Diagram

 

1

 

wwww.EntraPASS.com  

8641 S. Warhawk Rd., Conifer, CO 80433 - Tel: 303-670-1099 - Email: Patrick.McAllister@EntraPASS.com

 wwww.EntraPASS.com / 8641 S. Warhawk Rd., Conifer, CO 80433 - Tel: 303-670-1099 - Email: Patrick.McAllister@EntraPASS.com

Summary of Contents for E-PASS-21W

Page 1: ... Prog W grammin ng Instr ruction ns wwww EntraPASS com 8641 S Warhawk Rd Conifer CO 80433 Tel 303 670 1099 Email Patrick McAllister EntraPASS com wwww EntraPASS com 8641 S Warhawk Rd Conifer CO 80433 Tel 303 670 1099 Email Patrick McAllister EntraPASS com ...

Page 2: ...toshunt alarmcontactsontheaccessdoor gatetoprevent triggeringof analarmwhenauthorizedaccessoccurs The AK 21Wis powered from a 12 24 Volt AC or DC source Power can be obtained from the access device or a separate power supply The EEPROM memory retains all entry codes and programming even without power An internal jumperisprovidedtoresetthemastercode TheMainRelayhasa5Amp capacity The Auxiliary Relay...

Page 3: ...VDCMAX AUXILIARY REQUEST TO EXIT 6 EARTHGROUND 5 OUTPUT 3 COM 4 OUTPUT 3 3 AUXILIARY OUTPUTS REQUEST TO EXIT BUTTON TOALARM SYSTEM ALARM CONTACT 7 COM RELAY1 AMP 8 N C 28VDCMAX OUTPUT 4 2 OUTPUT 4 COM 1 100mAMAX TOCOMMON GROUND STAKE REQUIREDWIRING OPTIONALWIRING OTHERWIRING NOTES 1 ALARMSHUNT SET FORAUXILIARY RELAY 2 TERMINALBLOCK 2 TERMINAL8 SETFORDOORSENSE CAUTION IF THE UNIT IS AC POWERED MAKE...

Page 4: ...ITTHEBOTTOMTABOF THEFACEPLATEINTOTHE SLOTONTHEKEYPAD 4 SNAPTHETOP OFTHEKEYPAD INTOPLACE Install the Electrical Box and Mounting Plate The keypad is designed to fit into a single gang electrical box The box must be deep enough to accomodate the protective plastic enclosure Select a location near the controlled door and choose a convenient height for the keypad Be sure there is good wiring accessibi...

Page 5: ...ther a door sense or inhibit input Both features cannot be used at the same time To use the door sense feature to detect forced entry or door ELECTRIC DOOR STRIKE AK 21WREARVIEW TERMINAL BLOCK2 TB2 3 N O 4 COM 5 N C 6 7 8 TERMINAL BLOCK1 SENSE 8 COM 7 6 EARTHGROUND 5 4 3 TERMINAL MAIN RELAY 5AMPSMAX N C DOOR SENSE SWITCH GROUND STAKE ajar conditions install a normally closed door switch on the doo...

Page 6: ...will turn off until programming begins After a programming option number is entered the yellow indicator will blink This shows that the AK 21W is ready to accept the new programming data After the new data entry is complete the yellow indicator will flash while the data is being stored The green indicator will light if the data is accepted The red indicator will light if any programming data is en...

Page 7: ...ter too many incorrectentrycodeattempts Thelockouttimeis60seconds Press 1 3 Output Output OutputtoActivate 0 4 1 MainRelay 2 AuxiliaryRelay 3 Output 3 4 Output 4 0 NoOutput Main Relay On time Default 2 Seconds SetsthelengthoftimetheMainRelayactivateswhentriggered Press 2 1 Seconds Seconds Outputtimeinseconds 0 60 Auxiliary Relay On time Default 2 Seconds SetsthelengthoftimeAuxiliaryRelayactivatesw...

Page 8: ...s 3 00 W L Voltage 12 24Vo Current 30mAty Outputs MainRe Form Auxiliary Form Solidsta Short ENTAL perature 22 Fto Humidity 5 to95 LIMITED WAR oduct is warranted months The Warr ds only to wholesa distributionchanne ould inquire from th There are no obli damagesarisingo r otherindirect dam ofremoval installat iesformerchantabili ation Date as labeled rrantiesexpressor urnedfor warrantys ct Linear T...

Reviews: