background image

Beep Sou

Selects whe

Beep Sou

Selects whe

Beep Sou

Selects whe

Keypad L

Sets the nu
“locks out”.

 

Anti-pass

Sets the len

RESETT

Master Re

 

CAU
the e
prog
ALL 

STEP 1 

D

STEP 2 

P

STEP 3 

A
d

STEP 4 

R
r
in

Resetting

STEP 1 

O

STEP 2 

L
m

STEP 3 

W
T
h

STEP 4 

R

T

nds During A

ether or not the key

Pre

Sou

nds During O

ether or not the key

Pre

Sou

nds During O

ether or not the key

Pre

Sou

Lockout Coun

umber of incorrec

Pres

Attempts 

= Nu

sback Time 

gth of time an ent

Pres

Minutes 

=Time 

TING KEYPAD

eset

 

UTION: Perform

entire memory

grammable op

 ENTRY CODE

Disconnect pow
Press and hold 
Apply power to 
down until the r
Release the key

emain lit until t

ndicator will go

g the Master C

Open the AK-2
Locate jumper J
master code.

 

With power app
The keypad will
has been reset
Replace jumpe

THE MASTER PR

Auxiliary Relay

ypad beeps during

ess: 

4

 

2

 

#

 

Sou

und 

= 1 forYes, = 0

Output #3 

ypad beeps during

ess: 

4

 

3

 

#

 

Sou

und 

= 1 forYes, = 0

Output #4 

ypad beeps during

ess: 

4

 

4

 

#

 

Sou

und 

= 1 forYes, = 0

nt    

ct entry code attem

s: 

5

 

0

 

#

 

Attem

umber of attempts b

D

try code will not fun

ss: 

5

 

1

 

#

 

Minu

in Minutes (1-4), 0

ming a master

y of the AK-21

ptions to the fa

ES WILL BE E

wer from the ke

down the 

an

the keypad, co

red indicator sta

ys. The red and

he process is c

o out.

Code

 

1W case.

 

JP2. This  jump

plied to the key

l begin to beep
.

 

r JP2.

 

ROGRAMMING CO

g Auxiliary Relay a

und 

#

 

0 for No

 

g Output #3 activa

und 

#

 

0 for No

 

g Output #4 activa

und 

#

 

0 for No

 

     Defa

mpts allowed befo

mpts 

#

 

before lockout (2-7

Default: No An

nction after it is us

utes 

#

 

0 = No Anti-passba

r reset will clea
1W and return 

actory default 

ERASED.

 

eypad.

 

nd # keys.

 

ontinue holding

arts flashing.

 

d yellow indicat

complete, then 

er is used to re

pad, remove ju

p, signaling that

ODE IS NOW1234

Default: No

 

activation.

 

Default: No

 

ation.

 

Default: No

 

ation.

 

ault: 3 Tries 

fore the keypad 

7)

 

ti-passback

 

sed.

 

ack

 

ar 

all

 

values. 

 the keys 

tors will 

the yellow 

eset the 

umper JP2. 

t the code 

456.

 

AK-21W O

Keypad use

Users 
entry c

Up to e

All dig
code is
“0 0 4 

If the w
keypad

After a
green
progra

If the n
keypad
indicat
remain

After a
the an

SPECIFICA

MECHANICA

Dime

ELECTRICAL

V
C

O

ENVIRONME

Temp

H

LINEAR L

This Linear pro
twenty-four (24)
warranty extend
Linear’s normal
Consumers sho
warranty, if any.

consequential d
this product or
profit, or cost o

implied warrantie
Warranty Expira

of all other war

All products retu
(RPA#). Contac
important details

FCC NOTI

Changes or mo
manufacturer co
This equipment
device, pursuan
reasonable prot
equipment gene
and used in ac
communications
particular instal
television recept
is encouraged to

• Reorient o
• Increase t
• Connect t

which the

• Consult th

OPERATION 

ers request acc

of the AK-21W

code.

 

eight seconds 

its of the entry

s 0042, the use

2”.

 

wrong key is pr

d. The  correct  c

a correct code 

and the progra

ammed time.

 

number of inco

d lockout count
ting that the ke

n for one minut

a valid code ha

ti-passback tim

ATIONS

 

AL

 

mensions: 3.00” W

L

 

Voltage: 12-24 Vo
Current: 30 mA ty

Outputs: Main Re

Form

Auxiliary

Form

Solid sta

Short-

ENTAL

 

perature: -22°F to

Humidity: 5%to 95

LIMITED WAR

oduct is warranted
) months. The Warr

ds only to wholesa

distribution channe

ould inquire from th

There are no obli

damages arising o

r other indirect dam

of removal, installat

ies for merchantabili

ation Date as labeled

rranties express or

urned for warranty s

ct Linear Technical

s.

 

ICE

 

odifications not exp

ould void the user’s a

has been tested an

nt to Part 15 of th

otection against har

erates, uses and ca

ccordance with the i

s. However, there is

llation. If this equip
tion, which can be de

o try to correct the in

or relocate the rec

the separation bet

the equipment into

e receiver is conne

he dealer or an ex

cess by entering

W have up to 40

are allowed be

code must be 

er must enter

 

ressed, pressin

code can then 

is entered, the 

ammed relay w

orrect codes en

t, the yellow ind

eypad is locked 

te.

 

as been entered
me expires.

 

Wx 5.00” H x 3.00” 

Volts AC or DC

 

ypical, 150 mA ma

elay:

 

m“C” 5 Amps @28

y Relay:

 

m“C” 1 Amp @28 V

ate outputs (Outpu
t-to-common 100 m

o 149°F (-30°C to 6

5%non-condensin

RRANTY 

d against defects i
rranty Expiration Da

ale customers who b
els. Linear does not w

heir selling dealer 

gations or liabilitie

out of or in connec

mages with respec

tion, or reinstallatio

ity and implied warra

d on the product. 

Th

r implied.

 

service require a Re

Services at 1-800-4

pressly described in

authority to operate t

nd found to comply 

e FCC Rules. The

rmful interference 

an radiate radio freq

instructions, may ca

s no guarantee tha

pment does cause 

etermined by turning

nterference by one o

ceiving antenna.

 

etween the equipm

o an outlet on a ci

ected.

 

xperienced radio/T

g their code.

 

0 seconds to ke

etween each ke

entered. Exam

ng the 

key wi

be re-entered.

red indicator w

will activate for t

tered exceeds

dicator will ligh

out. The  locko

d, it will be unu

D

 

aximum 

8 Volts maximum

Volts maximum 
uts #3 & #4):

 

mA @24 VDC ma

65°C) 

ng

 

n material and wo

ate is labeled on the

buy direct from Lin
warrant this product

as to the nature o

es on the part of L
ction with use or p

ct to loss of proper

on. 

All implied warra

anties for fitness, are

his Linear LLCWarr

eturn Product Author

-421-1587 for an R

n this manual or ap

the equipment.

 

with the limits for a

ese limits are desig

in a residential in

quency energy and,

ause harmful interfe

at interference will 

e harmful interferenc

g the equipment off a

or more of the followi

ment and receiver.

rcuit different from

TV technician for h

ey in their 

eystroke.

 

mple: If the 

ill reset the 

 

will turn 

the 

the 

t, 

out will 

usable until 

aximum

 

workmanship for 

e product. This 

near or through 

t to consumers. 
of the dealer’s 

Linear LLC for 

performance of 

rty, revenue, or 

anties, including 
e valid only until 

ranty is in lieu 

rization Number 

RPA# and other 

pproved by the 

a Class B digital 
gned to provide 

nstallation. This 

, if not installed 

erence to radio 

not occur in a 
ce to radio or 

and on, the user 

ng measures:

 

mthat to 

help.

 

wwww.EntraPASS.com  

8641 S. Warhawk Rd., Conifer, CO 80433 - Tel: 303-670-1099 - Email: Patrick.McAllister@EntraPASS.com

Summary of Contents for E-PASS-21W

Page 1: ... Prog W grammin ng Instr ruction ns wwww EntraPASS com 8641 S Warhawk Rd Conifer CO 80433 Tel 303 670 1099 Email Patrick McAllister EntraPASS com wwww EntraPASS com 8641 S Warhawk Rd Conifer CO 80433 Tel 303 670 1099 Email Patrick McAllister EntraPASS com ...

Page 2: ...toshunt alarmcontactsontheaccessdoor gatetoprevent triggeringof analarmwhenauthorizedaccessoccurs The AK 21Wis powered from a 12 24 Volt AC or DC source Power can be obtained from the access device or a separate power supply The EEPROM memory retains all entry codes and programming even without power An internal jumperisprovidedtoresetthemastercode TheMainRelayhasa5Amp capacity The Auxiliary Relay...

Page 3: ...VDCMAX AUXILIARY REQUEST TO EXIT 6 EARTHGROUND 5 OUTPUT 3 COM 4 OUTPUT 3 3 AUXILIARY OUTPUTS REQUEST TO EXIT BUTTON TOALARM SYSTEM ALARM CONTACT 7 COM RELAY1 AMP 8 N C 28VDCMAX OUTPUT 4 2 OUTPUT 4 COM 1 100mAMAX TOCOMMON GROUND STAKE REQUIREDWIRING OPTIONALWIRING OTHERWIRING NOTES 1 ALARMSHUNT SET FORAUXILIARY RELAY 2 TERMINALBLOCK 2 TERMINAL8 SETFORDOORSENSE CAUTION IF THE UNIT IS AC POWERED MAKE...

Page 4: ...ITTHEBOTTOMTABOF THEFACEPLATEINTOTHE SLOTONTHEKEYPAD 4 SNAPTHETOP OFTHEKEYPAD INTOPLACE Install the Electrical Box and Mounting Plate The keypad is designed to fit into a single gang electrical box The box must be deep enough to accomodate the protective plastic enclosure Select a location near the controlled door and choose a convenient height for the keypad Be sure there is good wiring accessibi...

Page 5: ...ther a door sense or inhibit input Both features cannot be used at the same time To use the door sense feature to detect forced entry or door ELECTRIC DOOR STRIKE AK 21WREARVIEW TERMINAL BLOCK2 TB2 3 N O 4 COM 5 N C 6 7 8 TERMINAL BLOCK1 SENSE 8 COM 7 6 EARTHGROUND 5 4 3 TERMINAL MAIN RELAY 5AMPSMAX N C DOOR SENSE SWITCH GROUND STAKE ajar conditions install a normally closed door switch on the doo...

Page 6: ...will turn off until programming begins After a programming option number is entered the yellow indicator will blink This shows that the AK 21W is ready to accept the new programming data After the new data entry is complete the yellow indicator will flash while the data is being stored The green indicator will light if the data is accepted The red indicator will light if any programming data is en...

Page 7: ...ter too many incorrectentrycodeattempts Thelockouttimeis60seconds Press 1 3 Output Output OutputtoActivate 0 4 1 MainRelay 2 AuxiliaryRelay 3 Output 3 4 Output 4 0 NoOutput Main Relay On time Default 2 Seconds SetsthelengthoftimetheMainRelayactivateswhentriggered Press 2 1 Seconds Seconds Outputtimeinseconds 0 60 Auxiliary Relay On time Default 2 Seconds SetsthelengthoftimeAuxiliaryRelayactivatesw...

Page 8: ...s 3 00 W L Voltage 12 24Vo Current 30mAty Outputs MainRe Form Auxiliary Form Solidsta Short ENTAL perature 22 Fto Humidity 5 to95 LIMITED WAR oduct is warranted months The Warr ds only to wholesa distributionchanne ould inquire from th There are no obli damagesarisingo r otherindirect dam ofremoval installat iesformerchantabili ation Date as labeled rrantiesexpressor urnedfor warrantys ct Linear T...

Reviews: