13. Electrical connections DAB105CU
13.1 Commands
Contact
Function / Accessory
Description
1-2
GND-IIMP
NO
OPENING - INNER SIDE
Contact closure activates the opening operation.
The contact is always active if the ON-OFF-HOLD OPEN switch is present.
The contact is controlled by the COM400MHB/MKB function selector switch (if present).
1-3
GND-XIMP
NO
OPENING - OUTER SIDE,
MANAGED BY THE ON-
OFF-HOLD SWITCH
Contact closure activates the opening operation.
The contact is only active if the ON-OFF-HOLD OPEN switch is present.
DO NOT USE contact 1-3 or the ON-OFF-HOLD OPEN switch if the COM400MHB/MKB func-
tion selector switch is installed.
1-4
GND-OPD
NO
Overhead presence detector
(OPD), frame mounted
Overhead presence detector (OPD), frame mounted
When an OPD sensor is mounted on the frame or operator cover just above the swing side of the
door, it will–when activated–either keep the door open or closed. The sensor is not active during
opening and closing.
• a closed door will not open, if the OPD detects activity in the field.
• an open door will not close, if the OPD detects activity in the field.
• during opening, the door will continue to open, even if the OPD detects activity in the field.
• during closing, the door will continue to close, even if the OPD detects activity in the field.
• the OPD is not active in program mode OFF, manually opened door or during battery operation
(Power Save Mode).
1-5
GND-LOUT
DO NOT USE
Fix the label to the terminal board, taking care to apply it in the correct
direction (see the figure above).
6
1 2 3 4 5
6 7 8
1 2 3 4 5
1 2
3 4 5 6 7 8 9 10 11 12 13
6
12
34
5
ON
SPTE OPSP CLSP POAS CLTQ
LRN
HOT
PAG
MAT
SOS
ARM1
ARM2
LED
1
2
3
4
5
ON/OFF/HOLD OPEN
ENCODER
NON USAR
E
SINCRONIZZAZIONE ANTE DOPPIE
NON USARE
GND
IIMP
XIMP
OPD
LOUT
NON USARE
Apertura (controllata da ON/OFF
HOLD OPEN)
Rilevamento di presenza / pedana a pavimento
Apertura
24 V
+
-
MO
T
ORE
i
Optional extension units can be connected to the DAB105CU control panel: the DAB905ESE extension unit, or the DAB905ESA one,
or both, depending on the required functions.
SYNCHRONISATION OF DOUBLE DOOR WINGS
ON/OFF/HOLD OPEN
DO NOT USE
Motion sensor / mat safety
DO NOT USE
Opening (controlled from ON/OFF
HOLD OPEN)
Opening
DO NO
T USE
M
OTO
R