30
IP2159EN - 2017-06-12
Contact
Function / Accessory
Description
LRN
Automatic self-learning.
When the door is started up, and on every spring tensioning variation, CLTQ trimmer variation, replacement of the extension
units (DAB905ESE-DAB905ESA) or replacement of the electric lock / electic strike, it is necessary to perform an automatic
self-learning operation.
By pressing the LRN button, the door launches an opening/closing operation for the automatic self-learning of the positions
and of the opening/closing stops.
During the closure phase, the spring pushes the door to acquire the door wing weight.
By pressing the LRN button once, the door will open after 2 seconds.
Press the LRN button twice to open the door immediately.
In the case of double doors, the automatic self-learning operation must be carried out first on the MASTER door and then on
the SLAVE door.
The doors can be configured separately before connecting them with the synchronisation cable. In the case of door wing overlap
and separate configurations, the MASTER door must be kept open until the SLAVE door has completed its own self-learning
procedure.
Make sure the door is fully closed.
Move away from the door as soon as you have pressed the LRN button.
The door has no safety settings during the automatic self-learning procedure.
The door could suddenly slam shut.
DO NOT intervene during the self-learning procedure.
i
i
13.2 Outputs and accessories
Output
Description
+24V DC
GND
1 ...
6
Output for the power supply to the accessories 24V 400 mA max.
NB: the maximum absorption of 400 mA corresponds to the sum of all the accessories installed.
MOTOR
Motor connection
ENCODER
Encoder connection
ON/OFF
DO NOT USE
SYNC
Connection for cable for synchronisation between two swing doors.
For details about the operation, refer to the “SYNCHRONISED DOORS” chapter.
ON/OFF/HOLD
Connection of the ON/OFF/HOLD switch
ON
The IIMP and XIMP opening contacts are enabled.
OFF
The XIMP opening contact is excluded.
HOLD OPEN
Door open.
MOTION SENSOR
DO NOT USE