40
IP2159EN - 2017-06-12
18. Extension unit DAB905ESA (optional)
There is a command extension card for managing motion sensors, alarm indications and door status.
Remove the jumpers if a safety sensor is connected to terminals 1-2 and 1-3.
18.1 Commands
Contact
Function - Accessory
Description
1
2
GND-PIMP
NC
REVERSAL SAFETY CONTACT
INTERNAL SENSOR
The opening of the contact during the closure manoeuvre causes the movement to invert
(reopening).
NB: the opening of the contact of the motion sensor installed on double doors causes
both doors to re-open.
The sensor is not active in DOOR CLOSED mode (set via the function selector switch), or
when the door is opened manually due to a power failure or emergency closure (KILL).
1
3
GND-PDET
NC
OPENING SAFETY DEVICE
EXTERNAL SENSOR
The opening of the contact causes the movement to stop during the opening phase.
When the contact closes again, the automation resumes the interrupted opening opera-
tion. If the automation is closed, the opening of the contact prevents the opening operation.
Adjust the safety exclusion trimmer so that the sensor does not detect the wall during
the opening phase.
During the opening phase, the safety sensor takes priority over the motion sensor.
NB: the opening of the contact of the motion sensor installed on double doors causes
both doors to stop, except in the case of double exit doors.
Modify the operation of the double doors by changing the pre-configured parameters as
explained in chapter 13.
The sensor is not active in DOOR CLOSED mode (set via the function selector switch), or
when the door is opened manually.
5
4
24V-QTST
SAFETY TEST
Connect the QTST terminal of the control panel to the corresponding test terminal on the
safety device.
A test will be carried out on the safety device before every operation.
DAB905ESA
(optional)
DAB905ESE
(optional)
Torx T10
Long pin used for 2 Extension Unit
Short pin used for 1 Extension Unit only
5 mm nut driver
6
1 2 3 4 5
6 7 8
1 2 3 4 5
1 2
3 4 5 6 7 8 9 10 11 12 13
Fix the label to the terminal board, taking care to apply it in the correct
direction (see the figure above).
24 V DC
-
+
Sicurezza di inversione
lato interno
Sicurezza in apertura
lato esterno
Safety test
67
8
1234
5
NO
COM
NON USARE
NON USARE
LED
ESCLUSIONE
SICUREZZA
TRIMMER
ESCLUSIONE
SICUREZZA
NON USARE
NC
QTST
PDET
PIMP
GND
J1
J2
Uscita 24 V 1 A
i
i
(optional)
Torx T10
5 mm nut driver
(optional)
Long pin used f
or 2 Ext
ension Unit
Short pin used f
or 1 Ext
ension Unit onl
y
SAFETY
EXCLUSION LED
24V output 1 A
DO NOT USE
DO NOT USE
DO NO
T USE
Safety test
Safety contact on external
side opening
Reversal safety contact on
internal side
SAFETY EXCLU-
SION TRIMMER