instructions.
The installer must prepare and keep a maintenance record showing all the routine and
extraordinary maintenance work carried out.
8. Routine maintenance plan
Perform the following operations and checks every 6 months according to intensity of use of the
automation.
Without 230 V~ power supply and batteries if present:
-
Clean and lubricate the gate’s rotation pins and hinges with neutral grease.
-
Check the resistance of the fixing points.
-
Check the value of the capacity of the motor capacitor.
Reconnect the 230 V~ power supply and batteries if present:
-
Check the power adjustment.
-
Check that all commands and safety functions are operating correctly (photocells).
-
Check that the release system is working correctly.
-
Check that the batteries are working correctly (in continuity) if the VIVAH or E2HFC control
panel with battery kit is present, by switching off the power supply and performing several
manoeuvres. Once performed, turn on the 230 V~ power supply again.
Summary of Contents for Ditec FACIL
Page 1: ...Ditec FACIL www ditecentrematic com 3...
Page 2: ...2 3 Italiano 3 English 23 Fran ais 43 Deutsch 63 Espa ol 83 Portugu s...
Page 10: ...10 IP2132IT 2015 03 09 5 Dimensioni 333 188 285 285...
Page 30: ...30 IP2132EN 2015 03 09 5 Dimensions 333 188 285 285...
Page 50: ...50 IP2132FR 2015 03 09 5 Dimensions 333 188 285 285...
Page 70: ...70 IP2132DE 2015 03 09 5 Abmessungen 333 188 285 285...
Page 90: ...90 IP2132ES 2015 03 09 5 Dimensiones 333 188 285 285...
Page 110: ...110 IP2132PT 2015 03 09 5 Dimens es 333 188 285 285...
Page 123: ...123 3...
Page 124: ...3 Entrematic Group AB RGMXUVJDWDQ 6 DQGVNURQD Sweden www ditecentrematic com...