33
IP2253EN - 2017-01-10
6.5 Adjusting the mechanical end stops (standard on PWR50H/HR)
6.6 Adjusting magnetic limit switch (standard on PWR50HV)
Bring the gate wing to its fully open or closed position. Loosen the mechanical end stops with a
4mm Allen wrench, just enough so that they can slide along the drive screw, then move them up
against the split nut and fix them in place.
Bring the gate wing to its fully open or closed position. Loosen the limit switches with a Phillips
screwdriver, just enough so that they can slide along the guide, then bring them above the split
nut [16] until the magnetic sensor is activated. Fix them in place.
4 mm
4 mm