35
IP2253EN - 2017-01-10
Carry out the following operations and checks every 6 months or 36.000 cycles.
Disconnect the 230V~ power supply and batteries (if present):
- Clean and lubricate the gate rotation pins, hinges and drive screw with neutral grease.
- Check the state of wear of the brushes [12], and replace them if necessary.
- Check the resistance of the fixing points.
- Check the electrical connections are in good condition.
Reconnect the 230V~ power supply and batteries (if present):
- Check the power adjustment.
- Check all the commands and safety functions (photocells) are operating correctly.
- Check the release system is working correctly.
- If batteries are fitted, check they are working properly (in continuity) by disconnecting the power supply
and performing a series of consecutive operations. At the end, reconnect the 230V~ power supply.
7 . Routine maintenance plan
The packaging components (cardboard, plastic, etc.) must be separated out for recycling.
Refer to the local disposal regulations before proceeding.
The packaging materials must not be discarded in the environment or left within reach of chil-
dren, as they are a potential source of danger.
To dispose of electrical and electronic equipment, batteries and accumulators correctly,
take the product to the differentiated disposal and recycling centres, respecting the regulations
in force.
NB: for spare parts, refer to the spares price list.
8 . Troubleshooting
i
Problem
Possible cause
Operation
The gate doesn't
open or close
No power supply.
Make sure the mains supply is active.
Gearmotor released.
See the release instructions.
Photocells occupied.
Check the photocells are clean and op-
erating correctly.
Permanent STOP command.
Check the STOP command or the con-
trol panel.
Faulty selector.
Check the selector or control panel.
Faulty remote control.
Check the condition of the batteries.
Electric lock not working.
Check the lock is positioned and work-
ing correctly.
The gate opens,
but it doesn't close
Photocells occupied.
Check the photocells are clean and op-
erating correctly.
9 . Disposal