READ & WRITE DATA WITH EXTERNAL DEVICES
MODBUS
141 |
P a g e
Copyright © 2021 BF ENTRON and/or its affiliates. All rights reserved
Product Model:
iPAK2v2
Firmware Version:
V2.10
May 22 | Doc No 700253-2
Variable
Channel
Address offset
Type
Description
Weld program [nn]
%IXnn.0.7
BOOL
AV8 state 1 = ON
Squeeze force
Weld program [35]
%IW35
WORD
0
–
327672
Pre-heat force
Weld program [36]
%IW36
WORD
0
–
327672
Cool1 force
Weld program [37]
%IW37
WORD
0
–
327672
Upslope force
Weld program [38]
%IW38
WORD
0
–
327672
Main heat force
Weld program [39]
%IW39
WORD
0
–
327672
Cool2 force
Weld program [40]
%IW40
WORD
0
–
327672
Downslope force
Weld program [41]
%IW41
WORD
0
–
327672
Post-heat force
Weld program [42]
%IW42
WORD
0
–
327672
Hold force
Weld program [43]
%IW43
WORD
0
–
327672
Off force
Weld program [44]
%IW44
WORD
0
–
327672
Force low limit
Weld program [45]
%IW45
WORD
0
–
99
Force high limit
Weld program [46]
%IW46
WORD
0
–
99
Selected WAV
Weld program [47]
%IW47
WORD
0
–
7
Current low limit
Weld program [48]
%IW48
WORD
0
–
99
Current high limit
Weld program [49]
%IW49
WORD
0
–
99
Selected electrode
Weld program [50]
%IW50
WORD
0
–
7
Linked program
Weld program [51]
%IW51
WORD
0
–
255
Reserved
Weld program [52]
%IW52
WORD
Reserved
Weld program [53]
%IW53
WORD
Reserved
Weld program [54]
%IW54
WORD
Reserved
Weld program [55]
%IW55
WORD
Reserved
Weld program [56]
%IW56
WORD
Reserved
Weld program [57]
%IW57
WORD
C-Monitor
Shunt limit
Weld program [58]
%IW58
WORD
0
–
99 %
C-Monitor
Wear limit
Weld program [59]
%IW59
WORD
0
–
99 %
Reserved
Weld program [60]
%IW60
WORD
Attributes2
Weld program [61]
%IW61
WORD
Inhibited
Bit 0
%IX61.0
BOOL
0 = enable,1 =
inhibit
C-Monitor Shunt enable
Bit 1
%IX61.1
BOOL
0 = off, 1 = on
C-Monitor Wear enable
Bit 2
%IX61.2
BOOL
0 = off, 1 = on
Retry enable
Bit 3
%IX61.3
BOOL
0 = off, 1 = on
Motor valves1
Weld program [62]
%IW62
WORD
Reserved
Weld program [63]
%IW63
WORD
2 Divide value by 898.99 for kN. Divide value by 4 for lbf
Table 52: Weld Program Parameter Data Structure