9.10.2
Programming Valve Delay Parameters using WSP3
The example step-by-step instructions for programming forge delay using the WSP3 in
Table 72
.
Program data as per
Step
Description
Screen / Parameters
Key Inputs
1
The Status Screen will be
displayed on the WSP3
2
Press the
F
key to navigate to
the <<<
Main Menu
>>>
To Enter Menu
3
Scroll down to the
Edit
Program
line using the Down
arrow then press
RETURN
key
To scroll Down
To Enter Menu
4
Select correct
Program
number using + and - keys
Use the +/- keys to alter a selected
parameter.
5
Scroll down to
Edit Valves
line and press
RETURN
key
To scroll Down
To Enter Menu
6
Use the down arrow to select
when the valve output comes
on in sequence.
Use the right arrow to select
the
valve number
to come
on eg
valve 8
.
To scroll Down
To go Right
Ready
▌
-- 0 A
PROG 0
-
▌
- 21.0 A
5.00 kN
--
▌
0 A
~30.5%
EDIT PROGRAM
<<<PROGRAM 0>>>
EDIT VALVES
<<<
VALVES >>>
WAV
: . . . . . . . .
SQUEEZE:
. . . . . . . .
UPSLOPE:
. . . . . . .
8
MAIN HEAT:
. . . . . . .
8
DOWNSLOPE:
. . . . . . .
8
HOLD:
. . . . . . .
8
<<< MAIN MENU >>>
USE PROGRAM 0
EDIT PROGRAM