TUTORIALS
Configuring & Calibrating iPAK2v2 with the WSP3 Pendant
212 |
P a g e
Copyright © 2021 BF ENTRON and/or its affiliates. All rights reserved
Product Model:
iPAK2v2
Firmware Version:
V2.10
May 22 | Doc No 700253-2
10.4.2
Reset & Turn Off Electrode Stepper
If the Electrode Stepper is enabled, it can corrupt the calibration process. It is recommended that the Electrode Stepper
be reset and disabled before calibrating the control.
Step
Description
Screen / Parameters
Key Inputs
1
From the Status Screen
press the
F
key
2
Scroll down to the
Edit
Electrode
line and press
RETURN
3
Scroll down to the
Edit
Stepper
line and press
RETURN
4
Scroll down to
ENABLE
STEPPER
liner and set to
YES
5
Scroll up to
RESET
STEPPER
and press the
RETURN
key
6
Scroll down to
ENABLE
STEPPER
and set to
NO
7
Press
F
key to return to
ELECTRODE
menu
Ready
▌
-- 0 A
prog 0
-
▌
- 11.7 kA
5.66 kN
--
▌
0 A
~30.5%
<<<MAIN MENU>>>
USE PROGRAM 0
EDIT PROGRAM
EDIT ELECTRODE
<<<ELECTRODE MENU>>>
EDIT COUNTER
EDIT STEPPER
<<<STEPPER MENU>>>
ENABLE STEPPER
YES
Use +/- keys to alter a
selected parameter
<<<STEPPER MENU>>>
RESET STEPPER
<<<ENAGLE STEPPER>>>
ENABLE STEPPER
YES
Use +/- keys to alter a
selected parameter