10. USER PHONE NUMBER DATABASE
The system comes equipped with a user database of 500 user capacity. When the phone number is set, the user will be able to control the
output (-s) by free of charge phone call. GS-500 user database allows to assign output C1, output C2 or both outputs (simultaneous control)
to a certain user. The supported phone number format is the following:
•
International (without (+) plus)
– The phone numbers must be entered starting with an international country code in the
following format: [international code][area code][local number], example for UK: 4417091111111.
GS-500 user database supports user validity and access restriction features. For more details, please refer to
10.1. User Validity and
Access Restriction
.
Optionally, a user name can be set that typically specifies the owner’s name of a certain phone number, for example
:
John
.
The phone number and user name (if any) are used when searching for a certain user in the database as well as they are automatically
added in the event log after the successful output control event (see
13. EVENT LOG)
.
Add user phone
number (and user
name)
SMS
SMS text message content:
ssss_N:ttteeellnnuumm
or
ssss_N:ttteeellnnuumm:user-name
Value:
ssss
– 4-digit SMS password;
ttteeellnnuumm
– up to 15 digits user phone number;
user-name – up to 16 characters user name.
Example:
1111_N:4417091111111:John
To add the user phone number using the USR/PROG button, please refer to the
following steps:
Add user phone number and assign output OUT1 to it
1. Keep the USR/PROG button pressed for 5 seconds.
2. The blue STATUS-LED light starts flashing every 2 sec for 10 minutes or until the USR/
PROG button is pressed again briefly.
3. Dial the system‘s phone number before the 10-minute period expires using the mobile
phone to program.
4. The blue LED goes out (OFF).
5. Phone number is added to user database and output OUT1 is assigned to it.
Add user phone number and assign output OUT2 to it
1. Keep the USR/PROG button pressed for 10 seconds.
2. The blue STATUS LED light starts flashing every 1 sec for 10 minutes or until the USR/
PROG button is pressed again briefly.
3. Dial the system‘s phone number before the 10-minute period expires using the mobile
phone to program.
4. The blue STATUS LED goes out (OFF).
5. Phone number is added to user database and output OUT2 is assigned to it.
Add user phone number and assign both outputs (OUT1 and OUT2) to it
1. Press the USR/PROG button shortly.
2. The blue STATUS LED light will light up for 10 minutes or until the USR/PROG button is
pressed again briefly.
3. Dial the system‘s phone number before the 10-minute period expires using the mobile
phone to program.
4. The blue STATUS LED light goes out (OFF).
5. Phone number is added to user database and both outputs are assigned to it.
Config
Tool
This operation may be carried out from the PC using the
GS-Configurator
software.
WEB
BROWSER
This operation may be remotely carried out from the PC using the web browser.
ATTENTION:
Space and colon characters are NOT allowed in the user names.
NOTE:
Multiple users can be added by a single SMS text message,
Example:
1111_N:4417091111111:John_ 4417091111112:_
4417091111113:Tom
NOTE:
Multiple users can be deleted by a single SMS text message,
Example:
1111_D:John_ 4417091111113_Mark
For more details on output control, please refer to
11. OUTPUTS
.