Choose or browse the firmware file (as per your browser)
and click on Update firmware to start the process.

The Status led will blink red during firmware mode.

The update progress is shown in real-time, and will take a
few seconds for the update to complete

When the update is complete, the page will refresh and
you will be taken to the home page – where you can
verify   the   firmware   version.   If  the   update  fails   for   any
reason, please try the same process again.

Since, Ethergate Mk3 will reboot after a firmware update,
please allow a few seconds for it to be refreshed in the
browser. Please wait until the update process is complete.

Reset button

The reset button restores the network configuration of
the Ethergate Mk3 to factory defaults:

DHCP is set to enabled 

Static IP address is mapped to the Serial number
of the unit (used if DHCP is unavailable).
For example, a Serial No. of 2176541 will have a
default Static IP address at 10.17.65.41 

Netmask is set to 255.0.0.0

To   successfully   reset   to   factory   defaults   the   Ethergate
Mk3, the following procedure must be performed:

Power off the unit 

Press and hold the Reset button.

While holding the Reset button, power up the
unit, and keep holding the button for 3 seconds.

Release   the   Reset   button   once   the   status   led
starts blinking red.

Wait 3 seconds and cycle power  

Art-Net Send Test

NMU can also be used to troubleshoot the DMX output on
your Ethergate Mk3. Art-Net Test can be accessed from the
top menu: Art-net   Art-net

 Test

 

When first opened, the Art-Net is set to Disabled, please set
it to Enabled, and then you can use either the DMX faders to
test one or more DMX channels,  or use the test-patterns
from the options available. Please set the Ethergate Mk3 to
be output and on the same universe as being used to send
Art-Net from NMU.

DMX Connector pin out 

5pin DMX OUT/ DMX IN

Pin 1: Ground 

Pin 2: Data - 

Pin 3: Data + 

Pin 4: NC 

Pin 5: NC 

Any suitable 3 to 5pin DMX adaptor can be used to connect
to   3pin   DMX   cables   or   fixtures.   Please   note   the   pinout,
before connecting to any non-standard DMX connector.

5

Summary of Contents for DMX ETHERGATE MK3

Page 1: ...onfiguration DHCP by default Easy firmware upgrades via any web browser Reset button to perform factory restore Inbuilt Auto ranging 90 260V Mains power supply Safety Do not expose the Ethergate Mk3 to rain or moisture doing this will void the warranty Do not remove the cover live voltage inside This unit is intended for indoor use only Basic Setup Right out of the box the Ethergate Mk3 is factory...

Page 2: ...ceed 2 for the same universe User action is required to allow proper DMX output Ethernet Link Speed is ON when there is an active Ethernet Link 100 mbps It will stay OFF 10 mbps Ethernet Activity This LED blinks when there is activity on the Ethernet network NMU NMU Node Management Utility is a free Windows and Mac application that is used to manage compatible ENTTEC DMX over Ethernet nodes NMU wi...

Page 3: ... enabled the router on your network is expected to automatically provide the IP address to the Ethergate Mk3 If no DHCP router server is present on the network the manual IP address will be used If for some reason your unit does not get an IP address via DHCP please restart the Ethergate Mk3 with the ethernet cable connected It will listen for DHCP on startup and wait for a few seconds before givi...

Page 4: ...ict and the output might have unexpected data HTP Merge Highest Takes Precedence Channels are compared one to one and the highest value is set on the output Merging is limited to two sources any additional sources will be ignored by Ethergate Mk3 If either one of the 2 sources of DMX stop the failed source is held in the merge buffer for 4 seconds If during the 4 second timeout the failed source r...

Page 5: ... will have a default Static IP address at 10 17 65 41 Netmask is set to 255 0 0 0 To successfully reset to factory defaults the Ethergate Mk3 the following procedure must be performed Power off the unit Press and hold the Reset button While holding the Reset button power up the unit and keep holding the button for 3 seconds Release the Reset button once the status led starts blinking red Wait 3 se...

Page 6: ...orough NC 27278 Australia USA Tel 61 3 9763 5755 Tel Fax 888 454 5922 Fax 61 3 9763 5688 email sales enttec com www enttec com 6 Item Value Input Voltage 90 260V AC Input Frequency 50 60Hz Weight 1 65 lbs 0 75 kg Shipped weight 3 19 lbs 1 45 kg Length 7 53 191mm Width 4 14 105mm Height 1 75 44 45mm Op Environment 0 50 C in non condensing environment Connectors 2x 5 Pin Female XLR bi directional DM...

Reviews: