background image

9

10

Step 1:Use the screwdriver to open on the right side of the cover plate
Step 2:Get through the cable to the connector
Step 3: And then plug the RJ45 on the PCB
Step 4: fasten the cable on the casing of Translate

Installation diagram

5 Operating Static

Monitoring Device EnverBridge is the core component created by Envertech, it realizes 
the connection between solar power plant and internet. As an intelligent 

communication gateway, EnverBridge uses Envertech’s Power Line Communication 
(PLC) technology to continuously monitor the data of energy harvest of solar power 

plant such as power, voltage, current and frequency; it can also transmit the real-time 
data of energy harvest to EnverPortal to realize the monitoring around the world.

Set aside a minimum functionality of the EnverBridge module, you can optional this 
EnverBridge modules to achieve the connection between PV power plant and the 
Internet. RJ45 cable should be simultaneously matching with EnverBridge module. 

5.1 Working Mode

The working modes of an Envertech EnverBridge are:  
Start up
Active
Fault
Standby

The detailed working mode descriptions are as below:  
Start up 
Start up mode is for a newly installed EnverBridge. This startup mode must base on the 
proper AC, micro-inverter, Ethernet cables connecting. 
Active
When the EnverBridge is in normal operation process, this insures that the power 
available from micro-inverter array is exported to the utility grid. 
Fault
If the system does not operate correctly, Envertech EnverBridge will stop automatically 
and enter into Disable mode. The Envertech EnverBridge system keeps detecting the 
disable information, it will be in disable mode until fault release. If the inoperative 
EnverBridge has been repaired and match to the electrical utility grid, the whole system 

would enter operation mode after 60 seconds to 5 minutes. Be aware that only qualified 

personnel should maintain the ENVERTECH Micro-Inverters. 
Standby
When the EnverBridge is in operation process but keeps with low voltage and current in 
micro-inverter side for a certain time. The EnverBridge manages transition from “Active” 
to “Standby”. In “standby” mode, Micro- Inverters keep detecting the energy output of 
each micro-inverter. When the output energy 
reaches the power generation conditions, the inverter would enter into “Active” from the 
“Standby” state. 

• The equipment maintenance only can be carried through 

  by service department of Envertech, or the service centre 
  or professional authorized by Envertech. Maintenance 
  personnel should be familiar with all the warnings in this
  manual and the proposed steps.

• Must be sure to disconnect the input and output power 

  before removalof equipment for maintenance. 

5.2 Grid-Connection

EnverBridge system connects grid automatically. It detects and monitors the 
performance of each PV module through each micro-inverter. When the output energy 
reaches the power generation conditions, the EnverBridge system begin  to collect the 
data from Microinverters.

Summary of Contents for EnverBridge

Page 1: ...er Operating Manual Model Number EnverBridge This manual is an integral part of the unit Please read the instruction manual carefully before installation operation or maintenance Keep this instruction...

Page 2: ...id Connection 5 3 Grid Disconnect 5 4 Installation checklist 5 5 Start Up Checks 6 LCD Abstracts 6 1 Brief introduction 6 1 1 Function of LCD 6 2 LCD 1602 interface 6 2 1 Start up interface 6 3 Monito...

Page 3: ...ruction DANGER The DANGER symbols in this manual and on the EnverBridge Indicate a hazard with a high level of risk which if not avoided will result in death or serious injury CAUTION The CAUTION symb...

Page 4: ...not respond for any quality assurance and other risks For Envertech EnverBridge Warranty Terms and Conditions see the appendix of this manual 3 4 PV PCS _ Caution risk of electric shock CE mark is at...

Page 5: ...t installed environments suitable for it s IP rating CAUTION The device is intended for fixed installation Located on a part that is not removable without impairing the operation of the unit CAUTION V...

Page 6: ...07mm 3W 700g Natural convection no fans 40 65 IP65 CE 5 Years 7 8 Use the Power Line Carrier Communication PLCC technology within Photovoltaic power plant By PLCC technology EnverBridge collects gener...

Page 7: ...inverter array is exported to the utility grid Fault If the system does not operate correctly Envertech EnverBridge will stop automatically and enter into Disable mode The Envertech EnverBridge syste...

Page 8: ...these tests The data should be recorded in an equipment log If the device is not operating properly or fails any test the device has to be repaired 1 Inspect the equipment and accessories for mechanic...

Page 9: ...168 0 201 indicates a normal network connection and 192 160 0 254 indicates an abnormal network connection The figure of power efficiency which shows at the beginning of the second line indicates the...

Page 10: ...e the EnverBridge from the system Only trained and authorized professional personnel WHO ARE FAMILIAR WITH THE REQUIREMENTS OF SAFETY is allowed to perform servicing and maintenance work 6 5 Applicati...

Page 11: ...nverBridge Wear gloves and safety glasses Disconnect the EnverBridge from the Grid Isolating device Clean the EnverBridge with wet cloth carefully Introduction Use the monitoring website EnverPortal d...

Page 12: ...ill the EnverBridge serial Number in the blank space for example 90000001 click OK and finish the registration 19 20 9 Contact Zhejiang Envertech Corporation Ltd Tel 86 579 8926 6326 Email info envert...

Reviews: