IMPORTANT WARNINGS

UV Lamp Notice

UV Light is harmful to bare skin and eyes and can cause temporary or cleanable loss of vision. Never 

look directly at the UV lamp while it is illuminated; doing so could cause loss of vision! Only view 

illumination through the window at the front of the unit. To prevent exposure to ultraviolet light, 

disconnect the power to the unit before servicing any part of the Therapure

®

 230H air purifier.

UV Lamp Disposal

If the UV lamp breaks, turn off the unit. Do not operate the unit with a broken lamp. Do not use a 

vacuum to clean up breakage. Sweep debris into a plastic bag and dispose of properly. Contact your 

local waste management authority for instructions regarding recycling and the proper disposal of old 

lamp(s). To order a replacement lamp, call 800.875.8577 or go to www.envion.com. 

Mercury Notice

Because the Therapure

®

 230H contains a light bulb and light bulbs contain mercury,  

Envion is required to provide the following warning:

 WARNING:

 This product can expose you to Mercury, a chemical which is known to the  

state of California to cause birth defects or other reproductive harm. For more information,  

visit www.P65Warnings.ca.gov.

Do not place your used lamp(s) in the trash. Disposal of any item containing mercury must be in 

accordance with any hazardous waste disposal or recycling laws and regulations of your state.

TPP

230H

TPP230H

3

Summary of Contents for 49314

Page 1: ...50075 02 MANUAL TPP230H UV AIR PURIFIER...

Page 2: ...MANUAL TPP230H UV AIR PURIFIER...

Page 3: ...ure 230H That s why your Therapure 230H comes with a one year limited warranty Once you ve experienced the purity of Therapure 230H air visit us at our website to find out more ways to improve the qua...

Page 4: ...RTS 5 OPERATING THE THERAPURE 230H AIR PURIFIER 6 Air Purifier Specifications 6 Getting Ready 7 Controls Settings 8 CLEANING MAINTENANCE 9 Cleaning the Permanent Filter 9 Maintenance UV Lamp 10 Cleani...

Page 5: ...is plug is intended to fit in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a qualified electrician Do not attempt to d...

Page 6: ...a plastic bag and dispose of properly Contact your local waste management authority for instructions regarding recycling and the proper disposal of old lamp s To order a replacement lamp call 800 875...

Page 7: ...PRODUCT BENEFITS Effectively reduces smoke pollen dust VOCs animal dander dust mites mold and bacteria 3 speed fan setting lets you select the desired cleaning level TPP230H TPP230H 4...

Page 8: ...ticles 4 UV Lamp Cover 5 Control Panel 6 Control Dial 3 fan speed settings Low Medium and High 7 UV VOC Button 8 Air Outlet Grill 9 Base of Unit 10 UV Lamp 7 UV VOC Button 5 Control Panel 9 Base of Un...

Page 9: ...fan speed 3 watt UV light lamp Net weight 10 3 lbs Dimension LxWxH 9 6 x 7 9 x 27 25 Replacement Parts Lamp TPP2400 Filter TPP240F Locate a level surface on which to place the Therapure air purifier...

Page 10: ...close to the source of air pollution is an effective way to improve indoor air quality Note DO NOT run the Therapure air purifier with a broken filter Replace the filter if the filter has a tear or a...

Page 11: ...has three different speeds of cleaning LOW MED and HI Turn the knob ONCE for LOW TWICE for MED and THIRD for HI UV Control Press the UV VOC control button UV VOC to turn on the UV lamp Press it again...

Page 12: ...e filter The inlet grill may be cleaned after unit is turned off and unplugged with a vacuum or a slightly damp cloth Cleaning the permanent HEPA Type filter steps 1 4 shown 1 Release the inlet grill...

Page 13: ...aximum effectiveness please replace the UV bulb annually If the lamp stops functioning or needs replacement please visit our web site at www envion com to order a replacement lamp Or call 800 875 8577...

Page 14: ...pressing on the locking latch see diagram of Main Parts 2 Remove the two bolts used to fix the UV lamp cover and remove the cover out from the unit 3 Unscrew the old UV lamp from the lamp base of the...

Page 15: ...to make sure filter and inlet grill is properly installed locked into place Reduced airflow or poor filtering The inlet or outlet grill may be blocked Cleanable filter may be clogged Check to ensure...

Page 16: ...roduct as specified in this product manual This warranty applies only to the original purchaser of the Therapure 230H air purifier ALL EXPRESS AND IMPLIED WARRANTIES FOR THIS PRODUCT INCLUDING IMPLIED...

Page 17: ...OCEDURES a Before instituting an arbitration if you have any dispute we strongly encourage you to contact the Company to try to resolve the matter by calling 800 875 8577 although you are not required...

Page 18: ...TPP230H 15...

Page 19: ...TPP230H TPP230H 16...

Page 20: ...TPP230H TPP230H 17...

Reviews: