Operating Instructions

T

URNING

 Y

OUR

 P

ELLET

 S

TOVE

 O

FF

:

• 

MANUAL and HI / LOW mode: To turn the unit OFF, simply press the ON / OFF button. This will stop 

the feed of pellets. The blowers will continue to operate and cool the stove down. When cool enough, 

the stove will turn off.

• 

AUTO / OFF mode: To turn the unit OFF, turn the thermostat down or off. 

DO NOT unplug unit while Combustion fan is operating.  

This may lead to smoke escaping from the stove.

S

LIDER

/D

AMPER

 S

ET

-U

P

:

This is used to regulate the airflow through the pellet stove. 
If the fire should happen to go out and the heat output indicator has been set on the lowest setting, the 

Slider Damper should be pushed in slightly, decreasing the air in the firebox.
If, after long periods of burning, the fire builds up and overflows the burn pot or there is a build up of 

clinkers, this would be a sign that the pellet quality is poor, this requires more primary air, the slider 

damper must be pulled out to compensate.  Pulling the slider damper out gives the fire more air.

The easiest way to make sure that an efficient flame is achieved is to understand the characteristics of 

the fire.

•  A tall, lazy flame with dark orange tips requires more air – Open slider (pull out) slightly.

•  A short, brisk flame, like a blowtorch, has too much air – Close slider (push in) slightly.

Figure 5: Thermostat Switch in ON/

OFF poition.

 







 







1

2

3

4

5

6

7

8

9

 







 







OPERATION

: When the thermostat contacts close, the unit will light 

automatically. Once up to temperature, the stove operates the same 

as in MANUAL. When the thermostat contacts open, the stove’s HEAT 

LEVEL and Fans will drop down to the LOW setting for 30 minutes. If 

the thermostat contacts close within the 30 min, the HEAT LEVEL will 

return to the previous MANUAL setting. If the thermostat contacts 

remain  open  the  stove  automatically  begins  its  shutdown  routine. 

The stove will re-light when the thermostat contacts close again.

Figure 6: Efficient Flame.

•    If the flame is in the middle of these two characteristics 

with a bright yellow/orange, active flame with no black 

tips then the air is set for proper operation.

The combustion exhaust blower is a variable speed blower 

controlled  by  the  heat  output  button.  This  blower  will 

decrease the vacuum pressure inside the stove and as the 

heat output button is turned down. 

SPECIAL NOTES:

 

Pellet quality is a major factor in how the Pellet stove will 

operate.  If  the  pellets  have  a  high  moisture  content  or 

ash content the fire will be less efficient and has a higher 

possibility of the fire building up and creating clinkers (hard 

ash build-up).

Summary of Contents for 50-1021

Page 1: ...NS COULD RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH Contact your building or fire officials about restrictions and installation inspection requirements in your area SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY THIS MANUAL IS PRINTED ON RECYCLED PAPER PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE OWNER S MANUAL 50 1021 ...

Page 2: ...Dimensions 6 Rating Label Location 6 Operating Instructions 7 Control Board Functions 7 Automatic Safety Features of Your Pellet Stove 7 Operating Your Pellet Stove 8 Turning Your Pellet Stove Off 9 Slider Damper Set Up 9 Routine Cleaning and Maintenance 11 Warranty 14 Installation Data Sheet 15 Table of Contents ...

Page 3: ...maximum Ash Content 1 maximum Premium grade 3 maximum Standard grade Moisture Content 8 maximum Heat Content approximately 8200 Btu per pound minimum ASH The ash content of the fuel and operation of your stove will directly determine the frequency of cleaning The use of high ash fuels may result in the stove needing to be cleaned daily A low ash fuel may allow longer intervals between cleaning CLI...

Page 4: ...sure that the structural integrity of the home is maintained and all construction meets local building codes Minor soot or creosote may accumulate when the stove is operated under incorrect conditions such as an extremely rich burn black tipped lazy orange flames If you have any questions with regard to your stove or the above mentioned information please feel free to contact your local dealer for...

Page 5: ...ds to start or freshen up a fire in the heater Keep all such liquids well away from the heater while it is in use SMOKE DETECTOR Smoke detectors should be installed and maintained in the structure when installing and operating a pellet burning appliance OPERATION The ash pan and door must be closed securely for proper and safe operation of the pellet stove Also ensure all gaskets on the door are c...

Page 6: ... 3 8 619 mm When not installing the optional Hearth Pad on the unit the minimum requirements for floor protection are a width of 243 8 depth of 263 8 Specifications DIMENSIONS Figure 1 Dimensions of EF5 6 RATING LABEL LOCATION The rating label is located on the inside of the ash pan cover ...

Page 7: ... will turn off after 60 seconds and then must be released and pressed again 5 SYSTEM LIGHT Responsible for signaling the state of the control board When the light is flashing during start up the stove is in an automatic start mode When the light is solid the Heat Level Setting can be altered 6 ON OFF BUTTON Used to turn the unit ON and OFF 7 HEAT LEVEL ADJUSTMENT When pressed will change the heat ...

Page 8: ...his time to change the desired Heat Level Output setting The convection blower room air blower will turn on The speed of this blower is controlled by the setting of the heat level output indicator The convection blower can be turned OFF by depressing the convection blower control button For the best efficiency and to prevent cycling the convection blower should be left on at all times When operati...

Page 9: ...s more air Open slider pull out slightly A short brisk flame like a blowtorch has too much air Close slider push in slightly Figure 5 Thermostat Switch in ON OFF poition 1 2 3 4 5 6 7 8 9 OPERATION When the thermostat contacts close the unit will light automatically Once up to temperature the stove operates the same as in MANUAL When the thermostat contacts open the stove s HEAT LEVEL and Fans wil...

Page 10: ... liner s holes Then dispose of the scrapped ashes from the liner and from inside the burn pot Place the burn pot back into the stove making sure that the pipes are properly inserted into the burn pot Place the liner back into the burn pot making sure that the ignitor hole in the liner is aligned with the ignitor tube Pushing the liner up against the ignitor tube If after long periods of burning th...

Page 11: ... dry soft cloth If the glass has build up that can not be removed with only the cloth clean the glass using paper towel and a gas appliance glass cleaner this may be purchased through most dealers If a gas appliance glass cleaner is not available use a damp paper towel dipped in fly ash to clean the glass After the glass has been cleaned use the dry soft cloth to wiping down the outside and inside...

Page 12: ...inished using the pellet appliance for the season unplug the stove for added electrical protection It is very important that the stove be cleaned and serviced as stated above CLEANING PLATED SURFACES Please clean all fingerprints off of all plated parts with denatured alcohol on a soft cloth before firing the unit each time Fingerprints etc can become permanently etched into the plating if not rem...

Page 13: ... THE COMPLAINT DEFECT PERIODICAL MALFUNCTION ETC The limited warranty covers defects in materials and workmanship as long as the products has been installed according to the manual s instruction If the product is damaged or broken as a result of mishandling or misuse the warranty does not apply Removal and re installation costs are not covered under this warranty It is the manufacturer s option wh...

Page 14: ...L NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy MAGNEHELIC AT INSTALL ___________________ INSTALLER S SIGNATURE _________________________________________ NAME OF INSTALLER _________________________________________ ADDRESS _________________________________________ _________________________________________ ___________________...

Reviews: