background image

50-1935 Heat 

Distribution Kit

Figure 1: Heat Distribution Kit’s Parts Diagram.

Please  ensure  that  your  Heat 

Disribution Kit has not been damaged.

IMPORTANT: When installing the Heat 

Distribution Kit, the clearances shown 

in Figure 12 must be maintained.

Rear of the Unit

Hot Air Duct Angle

Hot Air Duct

Duct Cover Plate

Rear Standoff

Rear of the Unit

Item

Description

1

Hot Air Duct

2

Hot Air Duct Angle

3

Fireplace Vent Duct

4

Fan Bezel

5

Front Access Cover

6

Fan

7

Fan Housing Assembly

8

Fan Housing Mounting Bracket

9

5” Round Flex Line Air Duct

Figure 2: Remove the duct cover.

1.  Remove the rear standoff and the duct 

cover plate from the back of the unit.

Figure 3: Install the hot air ducts.

2.  Insert the hot air duct and the hot air duct angle into the cut out 

(refer to Figure 3). Secure the ducts to the back of the fireplace 

through the pre-drilled holes with hex head screws.  

3.  Cover  the  hot  air  duct  opening  with  the  Fireplace  Vent  Duct 

(refer to Figure 4). Push the vent duct kit against the back of 

the fireplace and secure it in place with five (5) ¼” HWH self 

drilling screws. 

Summary of Contents for 50-1935

Page 1: ... Front Access Cover 6 Fan 7 Fan Housing Assembly 8 Fan Housing Mounting Bracket 9 5 Round Flex Line Air Duct Figure 2 Remove the duct cover 1 Remove the rear standoff and the duct cover plate from the back of the unit Figure 3 Install the hot air ducts 2 Insert the hot air duct and the hot air duct angle into the cut out refer to Figure 3 Secure the ducts to the back of the fireplace through the p...

Page 2: ... Air Duct Opening Fireplace Vent Duct Vent Duct Collar Fireplace Figure 5 Fan housing overall dimensions Figure 6 Minimum Installation Clearances for Fan 5 Mount and secure the fan housing assembly to the framing members or to the 2x4 wall studs using the mounting brackets and screws provided in the kit refer to Figure 7 Note The brackets have a guided flange which provides the minimum spacing req...

Page 3: ...ons Figure 11 Install fan bezel grille Figure 10 Optional install with two 2 heat distribution kits Optional Note An 8ft 2 4m 5 Aluminum Flex Vent is provided Extra length of 5 Aluminum Flex Vent can be added using a coupling provided by the installer 9 Attach the fan bezel to the fan cut out and secure the fan bezel to the wall board with screws 10 Cover the cut out with a fan grille When install...

Page 4: ...February 18 2015 www enviro com C 14548 52 1 4 1327mm to Header A A 90 2286mm to Internal Ceiling 60 1524mm Chase Minimum Width 44 5 8 1133mm Minimum 26 1 2 610mm Chase Minimum Depth Minimum Height from the base of the unit Figure 12 Q4 Installation Clearances with Heat Distribution Kit ...

Reviews: