8
3
/
4
"
(222mm)
14
3
/
8
" (365mm)
Fan Grille
(Not Supplied)
Fan Bezel
Fan Housing
Strain Relief
Ground
Cover Plate
Fan Housing
Figure 8: Wiring fan.
e) Secure the cover plate to the
back of the fan housing with
screws
f) Secure the service wires to the
strain relief
f) For wiring options see Figure 9.
8. Attach the 5” Aluminum Flex Vent
to the Fireplace Vent Duct Collar
with sheet metal screws or a vent
strap and run the vent to the Fan
Housing Vent Duct Collar. The Fan
Housing Vent Duct can be installed
through the rear or the bottom
of the Fan Housing as shown in
Figure 10.
ΙMPORTΑΝΤ: Maintain a minimum
of 2” (51mm) clearance between
the flex lines and combustible
materials.
Fan Housing
Vent Duct Collar
Fireplace Vent
Duct Collar
5" Aluminum
Flex Vent
Figure 9: Fan wiring options.
Figure 11: Install fan bezel & grille.
Figure 10: Optional install with two (2) heat distribution kits.
Optional Note:
An 8ft (2.4m) 5” Aluminum Flex Vent is
provided. Extra length of 5” Aluminum Flex Vent can be
added using a coupling provided by the installer
9. Attach the fan bezel to the fan cut out and secure the fan
bezel to the wall board with screws.
10. Cover the cut out with a fan grille.
When installed, the Power Vent Kit, must be electrically
grounded in accordance with local codes or, in the absence of
local codes, with the National Electrical Code, ANSI/NFPA 70,
or the Canadian Electrical Code, CSA C22.1.
WARNING: Electrical Grounding Instructions
This appliance is equipped with a three-prong (grounding) plug
for your protection against shock hazard and should be plugged
directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.
Periodic examination of venting systems should be done by a qualified agency.