8

" (365mm)

Fan Grille

(Not Supplied)

Fan Bezel

Fan Housing

Strain Relief

Ground

Cover Plate

Fan Housing

Figure 8: Wiring fan.

e)  Secure  the  cover  plate  to  the 

back  of  the  fan  housing  with 

screws

f) Secure the service wires to the 

strain relief

f) For wiring options see Figure 9.

8.  Attach the 5” Aluminum Flex Vent 

to  the  Fireplace  Vent  Duct  Collar 

with sheet metal screws or a vent 

strap and run the vent to the Fan 

Housing Vent Duct Collar.  The Fan 

Housing Vent Duct can be installed 

through  the  rear  or  the  bottom 

of  the  Fan  Housing  as  shown  in 

Figure 10.

  ΙMPORTΑΝΤ: Maintain a minimum 

of  2”  (51mm)  clearance  between 

the  flex  lines  and  combustible 

materials. 

Fan Housing 

Vent Duct Collar

Fireplace Vent 

Duct Collar

5" Aluminum 

Flex Vent

Figure 9: Fan wiring options.

Figure 11: Install fan bezel & grille.

Figure 10: Optional install with two (2) heat distribution kits.

Optional  Note:

  An  8ft  (2.4m)  5”  Aluminum  Flex  Vent  is 

provided. Extra length of 5” Aluminum Flex Vent can be 

added using a coupling provided by the installer

9.  Attach the fan bezel to the fan cut out and secure the fan 

bezel to the wall board with screws.

10. Cover the cut out with a fan grille.  

When  installed,  the  Power  Vent  Kit,  must  be  electrically 

grounded in accordance with local codes or, in the absence of 

local codes, with the National Electrical Code, ANSI/NFPA 70, 

or the Canadian Electrical Code, CSA C22.1.

WARNING: Electrical Grounding Instructions

This appliance is equipped with a three-prong (grounding) plug 

for your protection against shock hazard and should be plugged 

directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.

Periodic examination of venting systems should be done by a qualified agency.

Summary of Contents for 50-1935

Page 1: ... Front Access Cover 6 Fan 7 Fan Housing Assembly 8 Fan Housing Mounting Bracket 9 5 Round Flex Line Air Duct Figure 2 Remove the duct cover 1 Remove the rear standoff and the duct cover plate from the back of the unit Figure 3 Install the hot air ducts 2 Insert the hot air duct and the hot air duct angle into the cut out refer to Figure 3 Secure the ducts to the back of the fireplace through the p...

Page 2: ... Air Duct Opening Fireplace Vent Duct Vent Duct Collar Fireplace Figure 5 Fan housing overall dimensions Figure 6 Minimum Installation Clearances for Fan 5 Mount and secure the fan housing assembly to the framing members or to the 2x4 wall studs using the mounting brackets and screws provided in the kit refer to Figure 7 Note The brackets have a guided flange which provides the minimum spacing req...

Page 3: ...ons Figure 11 Install fan bezel grille Figure 10 Optional install with two 2 heat distribution kits Optional Note An 8ft 2 4m 5 Aluminum Flex Vent is provided Extra length of 5 Aluminum Flex Vent can be added using a coupling provided by the installer 9 Attach the fan bezel to the fan cut out and secure the fan bezel to the wall board with screws 10 Cover the cut out with a fan grille When install...

Page 4: ...February 18 2015 www enviro com C 14548 52 1 4 1327mm to Header A A 90 2286mm to Internal Ceiling 60 1524mm Chase Minimum Width 44 5 8 1133mm Minimum 26 1 2 610mm Chase Minimum Depth Minimum Height from the base of the unit Figure 12 Q4 Installation Clearances with Heat Distribution Kit ...

Reviews: