10
REMOVING BURNER CONTROLS:
1. Shut off gas supply to appliance.
2. Remove surround panels by pulling up then out. Disconnect gas line from the valve. Disconnect
harness at connector on side of unit.
3. Open the door and gently remove the logs. Remove the brick panel as per instructions in “Secondary
Installation - Removing and Installing The Brick Panels”.
4. Remove the burner tray assembly by removing the two screws in the center of the tray. Pull tray up
from the left side, lift tray up and out towards the left.
5. Undo the three screws that hold the burner control tray onto the back firewall. Lift the control tray up
on the left side and pull out. Remove wire connector from firebox.
6. Installation is the reverse. When installing the log set refer to “Secondary Installation - Log Set and
Ember Installation”.
Caution: Bleed lines before lighting and light pilot with door open.
A
DJUSTING
VENTURI
AIR
SETTINGS
• There is one venturi and one air shutter on this
appliance. The venturi has been set for installation
at sea level. Some adjustment may be required.
• To adjust for high altitude: open the lower louvers.
Locate the venturi between the burner and
control trays. Loosen the setscrews with a long
screwdriver and rotate the air shutter until an
efficient flame is achieved (refer to Figure 3).
Maintenance And Service
Figure 3. Venturi Adjustment