Initial Installation
QUALIFIED INSTALLERS ONLY
E
LECTRICAL
S
YSTEM
:
The fireplace must be electrically connected and grounded in accordance with local codes or, in the
absence of local codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE Part 1, SAFETY
STANDARDS FOR ELECTRICAL INSTALLATIONS, OR THE NATIONAL ELECTRICAL CODE ANSI / NFPA 70
in the US.
WARNING:
The electrical grounding instructions must be followed. This appliance is equipped with a
three-prong (grounding) plug for your protection against shock hazard, and should be plugged directly
into a properly grounded three-prong outlet. DO NOT cut or remove the grounding prong from this
plug.
Figure 9. Wiring Diagram For Fan Control.
CAUTION:
When servicing controls, label
all wires prior to disconnection. Wiring
errors can cause improper and dangerous
operation. Verify proper operation after
servicing.
Figure 10. Installation of the blower.
R
EMOVING
AND
I
NSTALLING
T
HE
B
LOWER
:
1. Shut off gas supply to appliance and turn unit off
2. Open the door and gently remove the logs. Remove the
brick panel as per instructions in “Secondary Installation -
Removing and Installing The Brick Panels”.
3. Remove the burner tray assembly by removing the two
screws in the center of the tray. Pull tray up from the left
side, lift tray up and out towards the left.
4. Undo the three screws that hold the burner control tray onto
the back firewall. Lift the control tray up on the left side and
pull out. Remove wire connector from firebox.
5. Disconnect the gas line to the nipple. Remove the three (3)
screws holding the burner control tray to the back firewall.
Lift tray up on left side and pull out.
6. Pull blower towards you and disconnect the wires from the
blower and remove.
7. To re-install, perform the preceding steps in reverse. When
installing the log set refer to “Secondary Installation - Log Set
and Ember Installation”.
Wire Size
Max. Length
14 gauge
100 ft (30.48 m)
16 gauge
60 ft (18.29 m)
18 gauge
40 ft (12.00 m)
20 gauge
25 ft (7.62 m)
22 gauge
18 ft (5.49 m)
Table 2. Recommended Thermostat Wire
Size.
15