13
Figure 15: Corner Installation.
1" (2.5cm)
1"
(2.5cm)
6"
(15 cm)
Floor Protection
Fresh Air Intake
Wall thimble
manufactured
by pellet vent
manufacturer.
Installation
c
orner
t
hrough
W
all
i
nStallation
- F
reeStanding
:
Figure 16: Straight through wall Installation.
Non-combustible
floor protection.
Existing floor
(combustible)
6"
(15cm)
1"
(2.5cm)
Wall
thimble
Fresh air
intake
45° elbow
12"
(30.5cm)
2. Install a non-combustible hearth pad
(where necessary).
3. Place the appliance 375 mm (15”)
away from the wall. If the stove is
to be set on a hearth pad, set the
unit on it.
4. Locate the center of the exhaust
pipe on the stove. Extend that line
to the wall. Once you have located
the center point on the wall, refer to
pellet vent manufacturer installation
instructions for correct hole size and
clearance to combustibles.
5. Install the wall thimble as per the
instructions written on the thimble.
Maintain an effective vapour barrier
in accordance with local building
codes.
h
orizontal
e
xhauSt
t
hrough
W
all
i
nStallation
:
Vent installation: install vent at clearances specified by the vent manufacturer.
A chimney connector shall not pass through an attic or roof space, closet or similar concealed spaces,
or a floor, or ceiling. Where passage through a wall or partition of combustible construction is desired,
the installation must conform with all local regulations, including those referring to regional, national or
European Standards. Use 80mm stainless steel vent pipe to exhaust the unit to the outside.
1. Choose a location for your stove that meets the requirements stated in this manual and allows
installation with the least amount of interference to house framing, plumbing, wiring, etc.