9
Installation
c
learanceS
to
c
ombuStibleS
- F
reeStanding
:
When installing this unit on a combustible floor (for example linoleum, hardwood flooring) a non-
combustible hearth pad must be under the unit. The pad must extend at least the width of the appliance
[22” (558 mm)] and at least the depth of the appliance plus 6” (153 mm) in front of the appliance [29 ¾”
(756 mm)].
Side wall to unit
- 6 inches (15 cm)
Back wall to unit
- 1 inches (2.5 cm)
Corner to unit
- 1 inches (2.5 cm)
Door front to edge of floor protection
- 6 inches (15 cm)
30"
(76 cm)
48"
(122 cm)
36"
(91cm)
6"
(152 mm)
1"
(25 mm)
1"
(25 mm)
6"
(152 mm)
Back Wall
Si
d
e
W
al
l
Ad
jace
nt W
all
Floor Protection
Figure 4: EF3 Freestanding Clearance to Combustibles.
Minimum Alcove width - 36 inches (91 cm)
Minimum Alcove height - 48 inches (122 cm)
Maximum Alcove depth - 30 inches (76 cm)
Figure 5: EF3 Freestanding Minimum Alcove Size.
c
learanceS
to
c
ombuStibleS
- F
ireplace
i
nSert
:
10" (25.4 cm) Mantel
8"
(20.3 cm)
8"
(20.3 cm)
S
id
e
W
al
l
Floor Protection; Minimum 6" (15 cm) in front of door
Figure 6: EF3 Fireplace Insert Clearance to Combustibles.
Refer to Figure 6.
Side wall to unit
- 8 inches
(20.3 cm)
Mantel projection
- 10 inches (25.4 cm)
Mantel to top of unit - 8 inches
(20.3 cm)
Top facing to unit
- 8 inches
(20.3 cm)
Side facing to unit
- 6 inches
(15.2 cm)
Floor protection
- 6 inches
(15.2 cm)
on either side and to the front must be
protected by non-combustible material.
These dimensions are minimum clearances but it
is recommended that you ensure sufficient room
for servicing, routine cleaning and maintenance.