background image

43

42

Jan 2018

Sherwood Industries Ltd. (“Sherwood”) hereby warrants, subject to the terms and 
conditions herein set forth, this product against defects in material and workmanship 
during the specified warranty period starting from the date of original purchase at retail. 
In the event of a defect of material or workmanship during the specified warranty period, 
Sherwood reserves the right to make repairs or to assess the replacement of a defective 
product at Sherwood’s factory. The shipping costs are to be paid by the consumer. 
All warranties by Sherwood are set forth herein and no claim shall be made against 
Sherwood on any oral warranty or representation. 
Conditions

 

A completed warranty registration must be submitted to Sherwood within 90 days 
of original purchase via the online warranty registration page or via the mail-in 
warranty registration card provided. Have the installer fill in the installation data 
sheet in the back of the manual for warranty and future reference.

 

This warranty applies only to the original owner in the original location from date of 
install.

 

The unit must have been properly installed by a qualified technician or installer, and 
must meet all local and national building code requirements.

 

The warranty does not cover removal and re-installation costs.

 

Sherwood Industries Ltd. reserves the right to make changes without notice.

 

Sherwood Industries Ltd. and its employees or representatives will not assume 
any damages, either directly or indirectly caused by improper usage, operation, 
installation, servicing or maintenance of this appliance.

 

A proof of original purchase must be provided by you or the dealer including serial 
number.

 

This warranty does not cover any discoloration of the safety screen mesh.

Exclusions

An expanded list of exclusions is available at www.enviro.com/help/warranty.html
This warranty does not cover:

 

Damage as a result of improper usage or abuse. 

 

Damage caused from over-firing due to incorrect setup or tampering.

 

Damage caused by incorrect installation.

To the Dealer

 

Provide name, address and telephone number of purchaser and date of purchase.

 

Provide date of purchase. Name of installer and dealer. Serial number of the 
appliance. Nature of complaint, defects or malfunction, description and part # of any 
parts replaced.

 

Pictures or return of damaged or defective product may be required.

To the Distributor

 

Sign and verify that work and information are correct.

Sherwood Industries Ltd.

6782 Oldfield Road, Victoria, BC . Canada  V8M 2A3

Online warranty registration: www.enviro.com/warranty/

Warranty for Enviro Gas Products

Category

One Year

Two Year

Limited Lifetime

 

(7yr) 

Parts 

1,2 

(unit serial number required)

Firebox Liner Panels 

3

Firebox 

Heat Exchanger

Burner

Ceramic Logs 

4

Ceramic Glass 

5

Pedestal / Legs 

(excluding finish)

Door Assembly

Surround Panels 

(excluding finish)

Exterior Panels 

(excluding finish)

Up to 5 years

Electrical Components

Exterior Surface Finishing 

Labour

1   

Whereas warranty has expired, replacement parts will be warrantied for 90 days from part purchase date.  Labour not included.  

   Unit serial number required.

2   

50-173 Westport Fan Kit covered for up to 5 years from purchase date.  Labour not included.  Unit serial required.

3   

Excluding damage to the finish caused by improper setup of the appliance, or color changes.

4

  Log set and panels excludes wear and tear or breakage caused by cleaning or service.

4

  Glass is covered for thermal breakage. Photos of box, inside of door, and unit serial # must be supplied for breakage due to shipping.

6

  Exterior Surface finishing covers plating, enamel or paint and excludes colour changes, chipping, and fingerprints.

Travel costs not included.

Summary of Contents for Berkeley-Nova

Page 1: ...perty damage personal injury or loss of life Installation and service must be performed by a qualified installer service agency or the gas supplier Version Fran aise www enviro com fr html 4001609 W A...

Page 2: ...plumber or gas fitter when installed within the Commonwealth of Massachusetts Other Massachusetts code requirements Flexible connector must not be longer than 36in a shut off valve must be installed o...

Page 3: ...e performed by a qualified installer service agency or gas supplier This installation must conform to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 o...

Page 4: ...Removal 12 Glass Door Removal 12 Burner Removal 13 Fuel Conversion 14 Initial Installation 17 Preparation for Installation 17 Clearance to Combustibles 17 Direct Vent 18 Venting Clearances 18 Approve...

Page 5: ...TERS CAN CGA 2 17 M91 R2014 GAS FIRED APPLIANCES FOR HIGH ALTITUDES CSA P 4 1 15 TESTING METHOD FOR MEASURING ANNUAL FIREPLACE EFFICIENCY This ENVIRO Berkeley Fireplace Has been certified for use with...

Page 6: ...rkeley Dimensions Rating Label Lighting Instructions Location The rating label and lighting instructions are located on a plate hanging on the back of of the unit 29 5 16 75 5 cm 4 5 8 11 7 cm 30 1 4...

Page 7: ...next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any pho...

Page 8: ...flames to Figure 47 on page 35 The ideal flame will be blue at the base and light orange above The flames should be of medium height If the flames look like this no venturi adjustment is needed If the...

Page 9: ...e Berkeley DO NOT FORCE IT If the unit is going to be serviced turn off the electrical power to the unit as well NOTE When the unit is turned on for the first time it should be turned onto high with t...

Page 10: ...eed of the blower The blower is pushing the heat from the fireplace into the room Gas Control Valve Dull click when turning on or off this is the valve opening and closing Maintenance And Service Rout...

Page 11: ...allation Log Set Installation section If any logs are damaged contact your nearest ENVIRO dealer Replacing the Glass The glass in the fireplace is a high temperature ceramic If the glass is damaged in...

Page 12: ...in Figure 12 To replace the glass door simply reverse the above procedure Warning Do not touch or attempt to remove the glass door if the fireplace is not completely cold WARNING Never operate the fir...

Page 13: ...3 Place your hands in the air slots in the burners as shown in figure 14 then pull forward and lift up to dis engage the venturi tubes 4 Continue to lift up and rotate the burner approx 45 degrees as...

Page 14: ...en L and P c Turn the pilot head a turn clockwise back to its original position Fuel Conversion TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY Please read and understand these instructions before...

Page 15: ...e the screw clockwise until a torque of 9 inch lbs WARNING Do not over tighten the screw It is recommended that you grip the wrench by the short side f Verify that if the conversion is from NG to LPG...

Page 16: ...e until the correct flame is achieved 13 Relight the main burner in both the HI and LO positions to verify proper burner ignition operation and proper flame appearance figure 47 page 35 Confirm the in...

Page 17: ...ng joist Check stove and flue system clearance requirements Locate the stove where it can be accessed by a gas supply line Locate the stove in a large and open room that is centrally located in the ho...

Page 18: ...and arrangement Because the length of the vertical and horizontal sections dramatically affects the burning efficiency of the fireplace certain guidelines have been set in Initial Installation Allowa...

Page 19: ...sheild 46DVA WT 4WT Wall thimble 46DVA SC SC Storm collar 46DVA WFS 4CS Fire stop 46DVA WS WS Wall strap support band 46DVA F6 4FA Flashing 0 12 to 7 12 roof pitch 46DVA F7 4FB Flashing 8 12 to 12 12...

Page 20: ...Berkeley A termination guard 50 3266 is required when the termination is within 7 2 13m of grade Figure 24 Minimum Vent Length Approved horizontal termination Approved through wall thimble 24 61 cm Mi...

Page 21: ...at may be opened C 12 in 30 cm Clearance from permanently closed window to prevent condensation D 24 in 60 cm Vertical clearance to ventilated soffit located above the terminal within a horizontal dis...

Page 22: ...number of elbows is ideal as they tend to disrupt air movement Using 45 elbows is preferable to using 90 elbows Also a shorter vent system will perform better than a longer one The total length of ho...

Page 23: ...e and Service section The firebox baffle must be removed next by removing the two front screws using a T20 screwdriver Figure 27 Next remove the restrictor set screws and install the restrictor at the...

Page 24: ...n The air gap prevents excessive heat from possibly melting the vinyl siding 5 Horizontal pipes must be supported every 3 feet 914 mm Plumber s all round strap will suffice 6 When running horizontal p...

Page 25: ...n the vent termination should be pointing up Run a bead of non hardening mastic around the edges of the vent cap to make a seal with the wall Ensure the proper clearances to combustibles have been mai...

Page 26: ...lashing to the roof with roofing nails Use a non hardening sealant between the uphill edge of the flashing and the roof Insure the roofing material overlaps the top edge of the flashing Verify that yo...

Page 27: ...ng should be framed to 10 254 mm x 10 254 mm inside dimensions in the same manner as shown in Figure 23 45 elbows x2 Wall strap Plumber s tape connected to wal strap 4 Any occupied areas above the fir...

Page 28: ...the wires are not pinched between the adaptor and the collar and or flue outlet Ensure that the opening of the Drafthood Adaptor is not blocked or obstructed Optional remote control receiver ON OFF Re...

Page 29: ...venting Venting Restrictions The vent lengths below are measured from the floor to the top of the flex venting and cannot run in the horizontal dimension Minimum 10 ft 3 05m Maximum 30 ft 9 14m SPILLA...

Page 30: ...afthood into a non combustible chimney the following optional finishing technique can be used CAUTION Installations where the flue connector or venting connects to or passes through combustible walls...

Page 31: ...s individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psig 3 45 KPa Always check for gas leaks with a soap and water sol...

Page 32: ...s For Electrical Installations or The National Electrical Code ANSI NFPA 70 in the US WARNING The electrical grounding instructions must be followed The fan kit is equipped with a three prong groundin...

Page 33: ...e unit Then remove the glass door by releasing the top spring latches 2 Next install the ember bed assembly as shown in Figure 41 by holding onto the slots in the ember bed The ember bed must be held...

Page 34: ...Figure 46 Final Top Log 6 Next Install the left and right top logs as shown in Figure 45 Note the locating notches on the bottom side of both logs areas highlighted 7 Install the last log on top on t...

Page 35: ...tion at ALL the burner ports If a long delay is noticed turn the appliance off and wait for it to cool down Then remove the glass and make sure none of the burner ports are blocked Maintenance Once a...

Page 36: ...taining bolts Figure 48 using a 1 4 socket and remove the damaged screen while noting the orientation Install the new screen 50 3243 by simply re installing the retaining bolts Re install the cast doo...

Page 37: ...screw check pilot head for damage Check thermocouple voltage at valve It must be greater than 5 mV If low replace thermocouple Air in gas line pilot dies while knob is depressed Bleed line Check gas l...

Page 38: ...50 1421 13 Heyco Strain Relief EC 044 14 Domestic Power Cord 115v EC 042 15 Log Set 9 pieces 50 3234 16 Ceramic Burner Assembly 50 3233 17 Front Door Glass w Gasket 16 875 x 21 0625in 50 3235 18 Fron...

Page 39: ...39 Parts List 21 1 24 25 2 9 5 14 13 19 20 23 3 11 12 4 6 10 7 8 18 16 22 17 27 15 26...

Page 40: ...led Antique Chestnut 50 3249 31 Cast Skirt Painted 50 3250 Cast Skirt Enameled Antique Chestnut 50 3251 32 Cast Right Side Painted 50 3252 Cast Right Side Enameled Antique Chestnut 50 3253 33 Cast Lef...

Page 41: ...ar une personne de service certifi ou qualifi Chaud pendant le fonctionnement Ne touchez pas Des br lures graves peuvent en r sulter Gardez les enfants les v tements meubles essence et autres liquides...

Page 42: ...42 Notes...

Page 43: ...ty screen mesh Exclusions An expanded list of exclusions is available at www enviro com help warranty html This warranty does not cover Damage as a result of improper usage or abuse Damage caused from...

Page 44: ...______________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy...

Reviews: