The Berkeley gas valve and control panel (Figures 5 & 6) are located behind the valve access door at the
front of the stove (Figure 4). To light the burner correctly follow the steps below:
Operating Instructions
For Your Safety, Read Safety Precautions And
Lighting Instructions Before Operating
A) Make sure the pilot is lit (see
P
ilot
l
iGHt
section)
.
B) Turn gas control knob COUNTER CLOCKWISE to ON.
C) Flip the burner switch, located at the top right rear of
the Berkeley, to ON (see Figure 7)
D) Turn the HI/LO knob to the desired fl ame height.
NOTE:
Check that all burner holes are lit.
TO TURN GAS FIREPLACE OFF:
Flip switch to OFF to turn off burners only.
If the
fi replace is to be turned off for the season, or for
servicing, turn the gas shut off valve to OFF located at the
bottom right on the backside of the Berkeley. DO NOT
FORCE IT. If the unit is going to be serviced, turn off the
electrical power to the unit as well.
NOTE:
When the unit is turned on for the fi rst time, it
should be turned onto high, with the fan OFF, for the fi rst
two to four hours.
This will cure the paint, logs, gasket
material, and other products used in the manufacturing
process. It is advised that a door or window be opened
as the unit will start to smoke, which can irritate some
people. After the unit has gone through the fi rst burn,
Figure 6. Control Panel
b
uRneR
L
ighting
:
Piezo Ignitor
Fan Control
turn the unit OFF, including the pilot, and let the unit get completely cold. Then remove the glass and
clean it with a good gas fi replace glass cleaner, available at your local Enviro dealer. See “
M
aintenance
a
nd
S
ervice
; G
laSS
d
oor
r
eMoval
”
and “
M
aintenance
a
nd
S
ervice
; c
leaninG
t
He
G
laSS
.”
Figure 7. Burner Switch
Burner Switch
O
L
I
T
P
T
P
T
H
TP
T
H
IN
OUT
H I
L
O
N
OF
O
F
LI
P
T
O
Hi/Low
Knob
Gas Control
Knob
Figure 5. Gas Valve Controls