38
Initial Installation
QUALIFIED INSTALLERS ONLY
If your C44I / C44ID has been
converted to LP using 50-3270
conversion kit use this venting
diagram.
Flame Appearence:
Pin point on the
map where your vent configuration will
lay. Remember to consider elbows in the
HORIZONTAL plane account for horizontal
distance as stated on the previous page.
Use the corresponding exhaust restrictor
accorinding to the graph. See the following
section in this manual for installation
details. Your climate and altitude may
alter what restrictor is required for your
particular application.
If your flame is low, flickery, and more blue
5’
(1.52m)
8’
(2.44m)
4’
(1.22m)
1’
(0.3m)
10’
(3.05m)
10’
(3.05m)
15’
(4.57m)
15’
(1.52m)
20’
(6.1m)
20’
(6.1m)
25’
(7.62m)
30’
(9.14m)
35’
(10.7m)
40’
(12.2m)
LP Vent
Position
then increase the restrictor one
size. If your flame is tall, thin, and
lazy then decrease the restrictor
one size. Use your judgement
after the unit has been running for
about 20 minutes. If your having
difficulty achieving a healthy
flame with LP then try opening
the air shutter completely.
Caution: Wait until the unit
has completely cooled before
changing the restrictor.
Figure 49: LP Vent Graph
Does your vent configuration
fall outside the limits?
Use our
power vent kit (50-3884) for a much
broader venting range.
**Vertical vent height does not account for elbows