20
E25i & E25 Gas fuel Conversion Instructions
Warning: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable
codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or
production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for
the proper installation of this kit. The installation is not proper or complete until the operation of the converted appliance is checked as specified in
the manufacturer’s instructions supplied with the kit
NG to LP parts list
50-3981
• 52 bullet orifice
• 1 x Rating Plate Conversion Label
• 1 x Valve Body Conversion Label
• Stepper Motor For IPI (ordered Separately) (50-3753)
LP to NG parts list
50-3982
• 38 bullet orifice
• 1 x Rating Plate Conversion Label
• 1 x Valve Body Conversion Label
• Stepper Motor For IPI (ordered Separately) (50-3870)
1.
Remove door
2.
Carefully remove logs, log stands and log grate from firebox. Place aside for re-installation.
3.
Insert door tool into slot used for log grate lift up and rotate out log deflector (show left)
4.
Using a T20 screwdriver remove the x4 screws holding down the burner mount.
5.
Slide burner and burner mount to the left. Lift out burner and burner mount together.
6.
Using a 3/8” socket remove the installed orifice.
7.
Insert new orifice and tighten.
8.
Using a 7/16” wrench loosen the pilot thread
by turning it 1/4 turn to the counterclockwise.
9.
Once loosened push the slider to the desired gas
type.
The gas type is written on the top of the slider.
Left to LP Right to NG
10.
Re-tighten pilot head with
1/4 turn to the clockwise.