24
Initial Installation
QUALIFIED INSTALLERS ONLY
WARNING:
Operation of this heater when not connected to a properly installed and maintained
venting system can result in carbon monoxide (CO) poisoning and possible death.
c
LeaRances
to
c
ombustibLes
:
Maintain sufficient clearances for operation, service
and maintenance.
• A minimum distance of 21” (533 mm) is required
from the centerline of the unit to the sidewalls.
• Minimum clearance for any combustible facing is
33” (762 mm) from the bottom of the unit.
• A 12” (305 mm) wide mantel can be mounted at a
minimum height of 42” (107 cm) from the bottom
of unit.
• No floor protection is required for any install height.
However it is still strongly recommended to use
12” of floor protection especially when carpet or
linoleom flooring are used in front of the insert.
• Unit may be installed with combustible material
underneath unit - no spacing required.
• Minimum ceiling clearance is 54” (137 cm) from
bottom of unit.
m
inimum
f
iRepLace
s
ize
:
Table 5: Minimum dimensions of fireplace for E25 to be installed into.
Width At Front
Width At Back
Height
Depth
Fireplace Dimensions
28” (711 mm)
20.8” (528 mm)
19.5” (495 mm)
13.5” (343 mm)
NOTE: Space must be provided for gas line on left side of unit for servicing purposes.
v
enting
:
WARNING: This appliance has been designed to draw room air for proper heat circulation
from the sides and bottom of the unit, and out the top front. Blocking or modifying these
openings in any way can create hazardous situations.
The vent length for the E25 must be between 10ft (3.05 m) and 40ft (12.2 m).
The E25 intake and exhaust must be connected to 3” dia. flexible venting, made of either aluminum or
stainless steel, leading into a vertical termination cap. The flue collars of this model will fit inside of a
standard 3” vent and must be fastened directly to the vent with three screws.. The exhaust vent and air
intake are both located on the top of the unit.
Check periodically that the vents are unrestricted. Also ensure that all direct vent pipes have been
properly sealed and installed after routine inspection or cleaning. The air intake and exhaust pipes must
be installed in the correct locations on the top of the E25.
42”
41”
40”
39”
38”
37”
36”
35”
34”
33”
1
2
3
4
5
6
7
8
9
10 11 12
MA
NTL
E H
EIGH
T
(F
ROM UNIT BOT
TO
M)
M A N T L E D E P T H
Minimum Mantle Clearances
12” MANTLE
INSTALLATION
NOT PERMITTED