26
Initial Installation
QUALIFIED INSTALLERS ONLY
e
xhaust
R
estRictoR
:
This fireplace has an internal exhaust restrictor rings. Usage of the restrictor rings is dependant on
the length of venting required and different installation requirements.
instaLLation instRuctions:
1. Plan your installation and clearances
to combustibles. The E25 may be
installed and vented into any solid
fuel fireplace that has been installed
in accordance with the National,
Provincial/State and local building
codes and has been constructed of
non-combustible materials. Also refer
C
learanCes
to
C
ombustIbles
section.
2. Remove door. See
m
aIntenanCe
anD
s
erVICe
- g
lass
D
oor
r
emoVal
.
2ft (0.6m)
Minimum
3ft (0.9m)
Minimum
Within
10ft (3m)
Roof ridge or
any other portion
of a building
Roof Clearances.
i
nstaLLing
the
e25:
• Remove the crate and packaging from the appliance and check to make sure there is no damage.
Carefully check the glass door. Do not use the unit if it is damaged. In the event damage is found,
please report it to your dealer as soon as possible.
• Carefully clean the fireplace and flue before installing the stove. Failure to do so may result in fumes
or soot being blown into the room and may cause a fire leading to death or serious injury.
3. Remove packaged log set and all wrapping material from the stove. Remove wrapping material from
the log set and check for any damage. If damage is observed, do not use unit and contact your local
dealer.
2.5”
2”
2.25”
The restrictor rings are installed on the exhaust
outlet The exhaust outlet is accessed from inside
of the firebox.
1.
Remove door.
2.
Undo the fasteners securing baffle.
3.
Use the wing nuts provided to secure
the restrictor rings to the exhaust outlet.
Note: The E25 comes from the factory without
any restrictor rings installed.
Use the restrictor rings
at your discretion.
Be sure a clean
healthy burn is
achieved after 15
minutes of burning on
High.