28
Initial Installation
QUALIFIED INSTALLERS ONLY
10. If the fireplace opening is lower than 24” (610 mm), remove the vent collar plate from the top of
the insert
by unlatching the hook located on the
center top of the stove above the door opening (see
Figure 29). Slide the collar plate backwards. Properly secure the vent collar plate to the flexible vent
pipe liner(s) previously installed in the chimney. Be careful not to over-stretch the liner(s).
11. Apply a bead of stove cement sealant to the top section of the Ø3” (76mm) exhaust vent collar plate.
Slide the Ø3” (76mm) flex vent over the flue collar and secure with three (3) sheet metal screws
evenly spaced.
Vent Collar Plate Latch.
Unlatch
Latch
12. Place a bead of high temperature silicone on the intake collar
of the fireplace, slide the Ø3” (76mm) flex intake liner over the
collar, secure the flex liner with three (3) sheet metal screws
evenly spaced.
13. Place the unit part way into the fireplace. Connect the gas
line to the ⅜” NPT fitting on the right side of the unit using
locally approved methods (see
I
nItIal
I
nstallatIon
-
g
as
l
Ine
C
onneCtIon
)
. Route the power cord so it can be connected to
the power supply.
14. As you push the unit into its final position in the fireplace, if
the vent collar plate was removed, reinstall it on the stove by
pulling it
into the brackets on top using the supplied tool and
latch it back in place (shown in Figure 30).
15. If needed There are 4 bolts in the bag that thread
into 4 nuts located in the bottom of the cabinet use the
bolts to level the unit.
Pull
Brackets