36
8. Re-install the firebox door, then the safety screen.
9. Run the unit for 15 minutes then adjust the venturi as needed using the door tool. above depicts
what the burn and flame appearance should look like when the log set is properly installed and
venturi adjusted.
When re-lighting the fireplace for the first time since the log set has been installed/replaced, watch
for ignition at ALL the burner ports. If a long delay is noticed, turn the appliance off and wait for it to
cool down. Then remove the glass and make sure none of the burner ports are blocked.
Maintenance:
Once a year, the logs should be removed and checked for deterioration or large amounts
of soot. A small amount on the bottom side of the logs is normal. Remove and replace the logs in the
same manner described above.
If new logs are required, contact your nearest ENVIRO dealer.
Never operate the fireplace with the glass door removed.
Secondary Installation