5
DIRECT VENT:
This type is identified by the suffix DV. This appliance draws all of its air for combustion from
outside the dwelling, through a specially designed vent pipe system.
This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372 m) above sea level.
In the USA: The appliance may be installed at higher altitudes. Please refer to your American Gas Association
guidelines which state: the sea level rated input of Gas Designed Appliances installed at elevations above 2000
(610 m) feet is to be reduced 4% for each 1000 feet (305 m) above sea level. Refer also to local authorities
or codes which have jurisdiction in your area regarding the de-rate guidelines.
In Canada
: When the appliance is installed at elevations above 4500 feet (1372 m), the certified high altitude
rating shall be reduced at the rate of 4% for each additional 1000 feet (305 m).
•
This appliance has been tested by INTERTEK and found to comply with the established VENTED GAS
FIREPLACE HEATER standards in CANADA and the USA as follows:
DIRECT VENTED GAS FIREPLACE INSERT HEATER
TESTED AND LISTED TO: ANSI Z21.88 / CSA 2.33 VENTED GAS FIREPLACE HEATERS
CSA 2.17 GAS FIRED APPLIANCES FOR HIGH ALTITUDES
CSA P.4.1 TESTING METHOD FOR MEASURING ANNUAL FIREPLACE EFFICIENCY
This ENVIRO E25 Fireplace Insert:
• Has been certified for use with either natural or propane gases. (See rating label.)
• Is not for use with solid fuels.
• Is approved for bedroom or bed sitting room. (IN CANADA: must be installed with a permanent wall thermostat
for bedroom installations. Consult the authority having local jurisdiction in your area.
IN USA: see current ANSI
Z223.1 for installation instructions.)
• Must be installed in accordance with local codes. If none exist, use current installation code CAN/CGA B149 in
Canada or ANSI Z223.1/NFPA 54 in the USA.
• Must be properly connected to an approved venting system and not connected to a chimney flue serving a
separate solid-fuel burning appliance.
• Is not approved for closet or recessed installations.
Codes And Approvals
IMPORTANT NOTICE (Regarding first fire up):
When the unit is turned on for
the first time, it should be turned onto high without the fan on for the first 4
hours. This will cure the paint, logs, gasket material and other products used in
the manufacturing process. It is advisable to open a window or door, as the unit
will start to smoke and can irritate some people. After the unit has gone through
the first burn, turn the unit off, let the unit get cold then remove the glass door
and clean it with a good gas fireplace glass cleaner, available at your local ENVIRO
dealer. See “
D
oor
r
emoVal
” and “
C
leanIng
t
he
g
lass
”
sections.
COLD CLIMATES:
NOTE:
In cold climates, additional insulation may be used on some venting. It is
recommended in cold climates to wrap the exhaust and intake venting for the final
few feet before termination.