9
for at least five (5) minutes to clear out any gas.
Turn on gas to the
heater.
2. Turn the gas control knob to pilot, push in and hold
Simultaneously, press the piezo ignitor several times until the pilot ignites.
Hold the gas control knob in for at least 30 seconds (Wait for the 3 beeps)
once lit. Check that the pilot has fully engulfed the thermocouple assembly.
The pilot should now stay lit on its own, release gas control knob.
Operating Instructions
For Your Safety, Read Safety Precautions And
Lighting Instructions Before Operating
TO TURN GAS FIREPLACE OFF:
Flip switch to OFF to turn off burners, turn the gas control knob to OFF to extinguish the pilot flame. Keep the
pilot flame
OFF
when not in use for long periods. If the fireplace is to be serviced, turn the gas shut off valve
OFF (DO NOT FORCE IT) and disconnect all electrical power sources. See (Figure 4) for control panel layout.
NOTE:
When the unit is turned on for the first time, it should be turned onto high, with the fan OFF for the first
two to four hours.
This will cure the paint, glass, gasket material, and other products used in the manufacturing
process. It is advised that a door or window be opened as the unit will start to smoke, which can irritate some
people. After the unit has gone through the first burn, turn the unit OFF, including the pilot, and let the unit get
completely cold. Then remove the glass and clean it with a good gas fireplace glass cleaner, available at your
local Enviro dealer (See
m
aIntenanCe
a
nD
s
erVICe
- g
lass
D
oor
r
emoVal
and
m
aIntenanCe
a
nD
s
erVICe
- C
leanIng
t
he
g
lass
).
Convection fan operation is optional, it will come on only when the fireplace is up to temperature (approximately
15 minutes). The speed of the fan can be changed by turning the fan control knob. The blower will continue to
operate automatically after the unit has been shut off (approximately 25 minutes).To turn the blower off, turn
the knob counter-clockwise until it “clicks” off
It is advisable not to operate the blower below
1
/
3
speed as it puts a strain on the windings of the blower which
could also cause premature fan failure.
b
uRneR
L
ighting
:
1.
Make sure pilot is lit, if not light it (see above).
2.
Turn gas control knob counter-clockwise to ON; if already ON, see next.
3.
Flip burner switch to ON.
4.
Turn HI/LO control knob to the desired flame height.
5.
Check that all burner holes are lit.
o
ptionaL
b
LoweR
p
iLot
L
ight
:
1. Turn off the gas to the fireplace. I
f not recently done, remove the glass and let the unit air out
Thermopile
Thermocouple